19
19
GND
Supplied Battery Ground
INP
Activate Gate (Push button activation when momentarily shorted to ground)
12V
Supplied Battery Voltage (Protected with 3 Amp fuse)
GND
Supplied Battery Ground
INP
Activate Gate (Push button activation when momentarily shorted to ground)
12V
Supplied Battery Voltage (Protected with 3 Amp fuse)
EDGE
Reverse edge input. When grounded, will stop and reverse gate if closing, resets close timer if gate is open.
EDGE
Reverse edge input. When grounded, will stop and reverse gate if closing, resets close timer if gate is open.
GND
Supplied Battery Ground
GND
Supplied Battery Ground
STOP
Stop input from a 3 button station (must remove STOP CIRCUIT JUMPER) Normally closed
CLOSE
Close input from a 3 button station (see program switch #5 for options)
OPEN
Open input from a 3 button station (see program switch #5 for options)
GND
Supplied Battery Ground
GND
Supplied Battery Ground
FREE EXIT
Opens gate if closed, stops and reverses gate if closing, resets close timer if gate is open.
GND
Supplied Battery Ground
SHADOW
Resets close timer when gate is open (also referred to as under gate loop)
GND
Supplied Battery Ground
SAFETY
Resets close timer if gate is open, stops and reverses if gate is closing. (Does not open a closed gate)
GND
Supplied Battery Ground
FIRE
When grounded, opens gate and holds gate open until released.
Clears “Hard Shutdown” mode of software.
UL
When grounded, opens gate and holds gate open until released.
Clears “Hard Shutdown” mode of software.
Optional Device Inputs
GND
Supplied Battery Ground
INP
Activate Gate (Push button activation when momentarily shorted to ground)
12V
Supplied Battery Voltage (Protected with 3 Amp fuse)