12
13 - SETTING THE LIMIT SWITCHES
MOTOR 1 LED - GREEN
MOTOR 2 LED - GREEN
MOTOR 1 LED - RED
MOTOR 2 LED - RED
The limit adjustments are located inside the control box between the circuit
board and motor assembly as shown to the right.
Increase travel for
movement to the left
Decrease travel for
movement to the left
Increase travel for
movement to the right
Decrease travel for
movement to the right
Limit adjustment knob
for left movement
Limit adjustment knob for
right movement
Limit adjustment knob
for left movement
- Increase travel
- Decrease travel
Limit adjustment knob
for right movement
- Decrease travel
- Increase travel
Limit adjustment
assembly
OPEN LIMIT
Green OPEN LED
1
.
Using the OPEN button on the front of the Control Board,
hold the button down until the gate reaches the fully
intended open position.
2
.
Adjust the Open Limit on the operator until the GREEN
light illuminates on the front of the control board as shown
above. The fully OPEN limit switch is now set.
Note: if red LED illuminates, reverse orange and white limit
wires
CLOSE LIMIT
Red CLOSE LED
3
.
Using the CLOSE button on the front of the Control
Board, hold the button down until the gate reaches the
fully intended closed position.
4
.
Adjust the Closed Limit on the operator until the RED light
illuminates on the front of the control board as shown
above. The fully CLOSED limit switch is now set.
Note: if green LED illuminates, reverse orange and white limit
wires
The control board is already in the “LEARNING MODE”
when shipped. If the board is not in “LEARN MODE”
press FUNCTION then select LEARN then SLIDE then
LIGHT, AVERAGE OR HEAVY, then press ENTER.
For dual gate installations - set one motor at a time.