888

VPB 500 UK

Technical Data

Corrosion protection

Copper

Volume, hot water heater

litre

490

Volume, coil

litre

6

Length, coil

m

15.7

Heating surface, coil

m

2

5.2

Immersion heater, supply

V

230

Immersion heater, maximum output

kW

9

Heat transfer, primary 60/50 °C, 50 °C HW temp at the top

kW

15.8

Heat content at 50 °C

kWh

23

Equivalent amount of hot water (40°C)*

litre

590

Heating time 13-60 °C, 9 kW

min

80

Re-heating time up to 60 °C, 340 litre

min

52

Charging pressure, expansion vessel

bar/MPa

3.5/0.35

Max. pressure, incoming cold water

bar/MPa

16/1.6

Max. pressure, hot water heater

bar/MPa

6/0.6

Max. pressure, primary side

bar/MPa

3/0.3

Operating pressure, secondary side

bar/MPa

5.5/0.55

Setting, expansion relief valve

bar/MPa

6/0.6

Max operating pressure, T&P-valve

bar/MPa

7/0.7

Max operating temperature, T&P-valve

°C

95

Discharge capacity T&P valve

kW

25

Max. power input

kW

25

Max. immersion heater length

mm

400

Height (excl. feet)

mm

1750

Net weight

kg

182

Gross weight

kg

678

Part no.

083 221

*  With a supply temperature of 10°C and hot water usage of 24 l/min.

Energy labelling

Supplier

NIBE

Model

VPB 500 UK

Energy efficiency class

D

Heat loss

W

135

Volume

l

496

Technical specifications

Summary of Contents for VPB 500 UK

Page 1: ...MOS 1536 4 VPB 500 UK 031421 INSTALLATION AND MAINTENANCE INSTRUCTIONS VPB 500 UK LEK...

Page 2: ......

Page 3: ...ned tube The water heater is designed and manufactured for a maximum cut off pressure of 6 bar Maximum permitted temperature is 95 C The insulation is polyurethane which provides excellent heat insula...

Page 4: ...at maximum normal temperature for at least one hour Thereafter the system must be drained of water and refilled Emptying the system by 1 Open the filling valve and the drain valve for the heating sys...

Page 5: ...ompression ring with a plug on the open part of the drain valve The heater must be supplied with a mixing valve which limits the temperature of outgoing hot water to 60 C If this valve is not fitted s...

Page 6: ...lve During draining air must be let into the heater by loos ening a hot water heater connector or a hot water tap When mounted in locations exposed to the risk of frost the hot water heater must be em...

Page 7: ...her heat source 28 mm XL 8 Docking connection incoming from other heat source 28 mm XL 5 HWC connection 15 mm XL 13 Solar connection in 22 mm HVAC components UA 2 Submerged tube docking 11 mm int UA 3...

Page 8: ...0 35 Max pressure incoming cold water bar MPa 16 1 6 Max pressure hot water heater bar MPa 6 0 6 Max pressure primary side bar MPa 3 0 3 Operating pressure secondary side bar MPa 5 5 0 55 Setting exp...

Page 9: ...h 108 LEK LEK Flexible hose Expansion vessel LEK LEK LEK Shut off valve 162 Pressure reduction valve 148 L E K Cold water inlet and expansion relief valve water heater 165 LEK LEK LEK Plug with cable...

Page 10: ...10 10 10 VPB 500 UK...

Page 11: ......

Page 12: ...33 Fax 97 17 29 33 E mail info volundvt dk www volundvt dk NIBE Systemtechnik GmbH Am Reiherpfahl 3 29223 Celle Tel 05141 7546 0 Fax 05141 7546 99 E mail info nibe de www nibe de CH NIBEW rmetechnik...

Reviews: