Technical specifications

Height

1 070 mm (increases 15 – 40 mm for adjustable feet)

Width

450 mm

Depth

880 mm

Weight

290 kg

Boiler water volume

65 litres

Voltage

230 V

Average output during wood firing

33 kW

Wood magazine volume

95 litres

Wood magazine width

300 mm

Wood magazine depth

550 mm

Filler door width

300 mm

Filler door height

250 mm

Max. permitted total current for connected 

units

10 A

Max. operating pressure/design pressure boiler

150/1,5 kPa/bar

Wood length

0,5 m

Fan

115 W

RSK number

620 13 94

Summary of Contents for VEDEX 3300

Page 1: ...MOS GB 0733 1 VEDEX 3300 M10528 INSTALLATION AND MAINTENANCE INSTRUCTIONS VEDEX 3300 LEK...

Page 2: ......

Page 3: ...__________________________ 9 Pipe installation Connection_ ______________________________________ 10 Flue gas thermometer______________________________ 10 Filling_ ____________________________________...

Page 4: ...bers in brackets refer to the section Component locations The boiler is designed for houses with water borne heating and is environmentally approved for accumulator tank firing This appliance is not i...

Page 5: ...of wa ter heater size or the length of coil Abbreviations HW Hot water CW Cold water S V Safety valve AV Shut off valve WH Water heater EX Expansion vessel SV1 Shunt valve SV2 Mixer valve CP1 Charge p...

Page 6: ...stops the fan when the boiler temperature exceeds the set value Charge thermostat Thisthermostat starts and stops the charge pump at the set value 20 100 40 80 60 0 120 2 1 bar 3 0 4 Indicator lamp f...

Page 7: ...door 66 pulling up the turbulator and brushing clean This should be done a few times between chimney sweep visits For optimum combustion and efficiency the boiler s sec ondary combustion chamber shou...

Page 8: ...fter the supply of secondary air Primary air control The control damper on the front of the boiler is used to distribute the air supply to the hearth In the left position the air supply is from the to...

Page 9: ...of wood are used stack these over the grate hole to wards the rear wall When the wood in the boiler has been burned and the flue gas temperature drops to 80 85 C and a mini mal bed of embers remains...

Page 10: ...take must be as large as the smoke pipe duct Chimney VEDEX 3300 has a vertical flue pipe connection with an external diameter of 133 mm Angled flue pipe supplied as standard Different chimney heights...

Page 11: ...amic grate Place the ceramic inserts in through the filler door First position the front stone B Then position the rear stones C and D followed by stones E and F Flame trough Open the combustion chamb...

Page 12: ...e component parts Note Flue gas thermometer VEDEX 3300 is supplied with an enclosed flue gas ther mometer which must be installed in the flue gas door outlet Filling Fill the boiler with water using a...

Page 13: ...the electrical panel for this type of docking See Electrical installation Reconnection When the boiler s temperature and flue gas temperature exceeds the set temperature on the relevant thermostat th...

Page 14: ...nnection also the charge pump Electrical circuit diagram Electrical installation Laddpump Max thermostat 3 only controls the boiler s fan and charge thermostat 19 only controls the external charge pum...

Page 15: ...070 590 85 20 40 1115 1150 170 R32 inv 125 159 inv R25 inv R32 inv 15 utv R25 inv 15 utv 370 450 R25 inv min 250 515 180 125 1275 Minsta avst nd till v gg 250 mm 125 70 1320 Technical specifications T...

Page 16: ...specifications 45 42 40 3 36 19 2 Component location boiler section Component location front panel 133 utv R25 inv 15 utv R25 inv 125 45 19 3 42 40 2 36 83 22 22 66 96 83 66 96 33 81 82 33 81 82 100...

Page 17: ...3 Front panel 36 Indicator lamp operation 40 Thermometer 42 Manometer 45 Control switch 64 Sight glass 65 Filler door 66 Soot door for convection part 68 Combustion door 81 Flow line R32 int 82 Expans...

Page 18: ...cessories LEK LEK LEK Charger pack 1 Part no 089 872 Contents 1 x non return valve connection 25 1 x charge pump 6 mvp with shutoff valves 1 x shunt valve for heating system connection 25 1 x circulat...

Page 19: ...ler water volume 65 litres Voltage 230 V Average output during wood firing 33 kW Wood magazine volume 95 litres Wood magazine width 300 mm Wood magazine depth 550 mm Filler door width 300 mm Filler do...

Page 20: ...wice a year for optimum function and a long serv ice life Check that the boiler is off and that no embers are in the combustion chamber Disconnect the fan from the electrical socket on the boiler Remo...

Page 21: ...into the flue gas fan when sweeping use the supplied cover plate as follows Remove the soot door Insert the cover plate over the hole as illustrated Reinstall the soot door to prevent soot exiting wh...

Page 22: ...20 VEDEX 3300...

Page 23: ......

Page 24: ...STAD NB Tel 0168 477722 Fax 0168 476998 E mail info nibenl nl www nibenl nl V lund Varmeteknik Filial af NIBE AB Brog rdsvej 7 6920 Videb k Tel 97 17 20 33 Fax 97 17 29 33 E mail info volundvt dk www...

Reviews: