Removing the insulation
The insulation can be removed to facilitate handling in
confined spaces.
■
Remove the temperature gauge and the covers over
the immersion heater connections.
■
Lift off the top cover and remove the insulation at the
top.
■
Remove the covers over the connections and the cover
discs.
■
Undo all the screws along the joining plate on all parts
of the jacket.
■
Remove the insulated jacket.
■
Remove the four insulated jacket sections; the outer
diameter of the accumulator tank decreases by 100
mm without the insulated jackets.
When the accumulator tank has been placed in the cor-
rect location, reinstall the removed components in the
reverse order.
Finally, fit all the supplied cover discs on the relevant
connections by pressing them over the connections.
NOTE
Fit the cover discs before the pipe installation
is made.
9
Chapter 3 |
For the Installer
NIBE UKV 20