The water heater is only designed for upright installa-
tion.

Position the water heater on a m base that can bear

its weight, preferably on a concrete

r or founda-

tion. Use the water heater’s adjustable feet to obtain
a horizontal and stable set-up.
Pipes must be routed from the safety valve to a suit-
able drain.
The water heater’s installation area should always
have a temperature of at least 10 °C and max 30 °C.

Supplied components

Mega Coil/Mega Coil-Solar 

Tundish

Elbow and drain cock - cold inlet

   Armoured hose

(expansion vessel)

Expansion vessel with holder

Motorized valve

Location

The kit of supplied items is supplied in a separate box.

Chapter 2 |

Delivery and handling

6

2 Delivery and handling

Remember to rotate the cylinder in a direction that 

allows easy access to the immersion heater and the

electrical box.

be

transported and stored vertically in a dry place.

The Titanium Megacoil/Megacoil-Solar should

 

Installer manual

MEGA COIL/MEGA COIL-SOLAR 

HOT WATER HEATER

Air to Water Heat Pump Domestic Hot Cylinders

TITANIUM MEGACOIL/MEGACOIL-SOLAR

 Installer manual

expansion relief valve

Pressure reduction valve, check valve 

Cold water inlet combination

and

Warranty Card

SERIAL NUMBER

YEAR OF MANUFACTURE

INSTALLATION DATE

GUARANTEE REGISTRATION CARD

IMPORTANT - Register your Guarantee now

C

OMPL

ET

E THI

S PA

G

E AND R

ETURN TO 

N

IB

E

INSTALLER NIBE REGISTERED NUMBER:

INSTALLER'S COMPANY NAME

ADDRESS

ADDRESS 

TELEPHONE

POSTCODE

EMAIL

CUSTOMER'S NAME

INSTALLATION ADDRESS

ADDRESS

POSTCODE 

TELEPHONE

EMAIL

INSTALLERS NAME (PLEASE PRINT)

INSTALLERS SIGNATURE

In order to register your guarantee, it is important that all details on  
this card are completed before it is returned.

The completion of a Benchmark Checklist is a condition of warranty but  
does not affect your statutory rights.

Please complete in block capitals.

NO.

For full terms and conditions, please see our website www.nibe.co.uk.

GB

U

K W

arranty 

C

ar

d  0948-1 art.nr 711318

CUSTOMER

INSTALLER

NAME OF NIBE PRODUCT INSTALLED

(solar coil only)

LEK

Solenoid valve 

(Megacoil Only) 

Titanium Megacoil/Megacoil-Solar

Summary of Contents for TITANIUM MEGACOIL 160L

Page 1: ...Air Source Heat Pump Domestic Hot Water Cylinders TITANIUM MEGACOIL MEGACOIL SOLAR Installer manual...

Page 2: ......

Page 3: ...ons 10 T P valve 12 Heat pump 12 Sun 12 Cold and hot water 13 Docking 13 5 Electrical installation 15 Sensors 15 Temperature limiter 16 6 Commissioning and adjusting 17 Filling and venting 17 Start up...

Page 4: ...iance is not intended for use by persons includ ing children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruc...

Page 5: ...stomers a comprehensive guarantee The product is guaranteed for 24 months for parts and labour from the date of installation or 33 months from the date of manufacture whichever is the shorter The NIBE...

Page 6: ...aller manual MEGA COIL MEGA COIL SOLAR HOT WATER HEATER Air to Water Heat Pump Domestic Hot Cylinders TITANIUM MEGACOIL MEGACOIL SOLAR Installer manual expansion relief valve Pressure reduction valve...

Page 7: ...pter 3 The water heater design 7 3 The water heater design MEGA COIL 160 200 300 L MEGA COIL SOLAR 200 300 L See page 8 for explanations TITANIUM MEGACOIL 160 200 300 L TITANIUM MEGACOIL SOLAR 200 300...

Page 8: ...tube for hot water sensor control UA2 Submerged tube for solar sensor control only UA3 Electrical components Temperature limiter motorized valve FD2 Miscellaneous Serial number plate PF 3 Adjustable f...

Page 9: ...0 mm maximum Tundish Metal discharge pipe from temperature relief valve to tundish Safety device e g temperature relief valve 300 mm minimum Metal discharge pipe from tundish with continous fall Possi...

Page 10: ...Docking connection w line 22 mm XL9 Docking connection return line 22 mm XL13 Solar w line 22 mm XL14 Solar return line 15 mm XL29 T P valve 10 Chapter 4 Pipe connections Dimensions pipe connections...

Page 11: ...80 10 11 EPD O ring 29 2x3mm 1 10 2 Mes R r Nippel Overgang G1 22mm 1 10 1 R RNIPPEL OVERG 1 22 MS 1 10 EPS Skumspakning el lokk 1 9 N A Thermodisc 300075 4011 1 7 N A O Ring 38x3 2mm 1 6 N A Element...

Page 12: ...upply and return are connected to the Titanium Megacoil Solar Coil 12 Chapter 4 Pipe connections T P valve Install the pipe for the T P valve as illustrated on page 9 Heat pump connections Connecting...

Page 13: ...water pipes Adjust the hot water system so that the temperature does not fall below 50 C at the ends of the system Docking Titanium MegaCoil 200 300 can be connected in several ways one of which is sh...

Page 14: ...lar heating Mega Coil Solar can be docked to a solar heating system in addition to the F2040 heat pump P BT12 AA25 EB1 BT3 BT1 To air sorce heat pump Mega Coil Mega Coil Solar can be docked with an ai...

Page 15: ...where it is only possible to connect one sensor use the submerged tube for control sensor UA2 Titanium Megacoil Megacoil Solar can also be supplemented with a solar sensor This is placed in the submer...

Page 16: ...FD1 is 230 V Connect temperature limiter FD2 and FD3 electrically to the motorized valves one to each heat source Temperature limiter wiring diagram 16 Chapter 5 Electrical installation Immersion hea...

Page 17: ...ter that comes out of the hot water tap is no longer mixed with air the water heater is full and the tap can be closed Filling and venting the charge coil Filling and venting 1 Open the g valve extern...

Page 18: ...diagram solar coil Connection w line solar heating system XL13 and connection return line solar heating system XL14 Titanium Megacoil Solar 200 18 Chapter 6 Commissioning and adjusting Titanium Megac...

Page 19: ...hrough the valve 3 Close the valve by releasing it Ifi t does not close automatically when released turn it anti clockwise slightly NOTE Do not remove or adjust any components that are part of this pr...

Page 20: ...W 12 12 12 Volume expansion vessel litre 18 18 24 42 Drawn off capacity Cold water temperature 10 C 8 Technical Titanium Megacoil 179 litre Volume net 8 5 litre Volume charge coil 45 59 kg Net weight...

Page 21: ...5 5 0 55 bar MPa Max pressure water heater 3 0 3 bar MPa Maximum pressure solar coil 16 1 6 bar MPa Max water supply pressure 6 0 0 6 bar MPa Max design pressure 3 0 0 3 bar MPa Exp vessel tap water c...

Page 22: ...alternative 13 To ground source heat pump 14 M Maintenance 19 General inspection 19 P Pipe connections 9 Cleaning the climate system 8 Cold and hot water 13 Connecting cold and hot water 13 Dimensions...

Page 23: ......

Page 24: ...e b e v l a v n o i s n a p x e d n a e v l a v f e i l e r e r u s s e r p d n a e r u t a r e p m e t d e n i b m o c a s a H No s e Y s n o i t a l u g e R g n i d l i u B e h t f o G t r a P o t...

Page 25: ...mments Signature SERVICE 3 Date Engineer Name Company Name Telephone Number Comments Signature SERVICE 4 Date Engineer Name Company Name Telephone Number Comments Signature SERVICE 5 Date Engineer Nam...

Page 26: ...NIBE Energy Systems Ltd 3C Broom Business Park Bridge Way Chesterfield S41 9QG Phone 0845 095 1200 Fax 0845 095 1201 info nibe co uk www nibe co uk nstaller manual GA COIL SOLAR COIL HOT WATER HEATER...

Reviews: