General
PCM 40/42 makes it possible to obtain passive cooling
from rock, groundwater or surface soil collectors. When
using a surface soil collector the quality of the ground
may limit the possibility of utilising passive cooling.
The ideal climate system is a floor system, which then
becomes both a cooling and a heating system. Kylan
startas när utetemperaturen överstiger inställd temper-
atur och regleras sedan via vald kylkurva. Room sensors
can be used for optimum comfort. To prevent condens-
ation, the lowest permitted supply temperature should
be chosen in menu 1.9.3.
NOTE
Choice of PCM 40 or PCM 42 depends on heat
pump capacity.
Contents
Wall bracket
1 x
Screw
2 x
Securing plate
1 x
T-coupling ø
22
(only PCM 40)
1 x
T-coupling ø28 (only PCM 42)
1
x
Mounting
Mount the cooling module on the wall.
NOTE
Ensure to post-tighten all hydraulic connec-
tions again, both inside and outside
PCM 40/42, after PCM 40/42 is installed and
mounted.
NOTE
Do not use the pipes as a handle.
Use the enclosed mounting bracket, which should be
screwed into place first, see the following illustration.
The cooling module is then hung on the bracket. It is
now possible to slide the cooling module sideways,
which facilitates the fitting of the pipes.
N.O
NOTE
Install the accompanying securing plate any-
where at the bottom rear of the cooling
module for further fastening.
14
English
GB