Transport and storage
GV-HR 130 should be transported and stored in the dry.
Assembly
GV-HR 130 is installed in the roof using the enclosed
roof brackets. Noise from the fans can be transmitted
to the brackets.
• Install GV-HR 130 on an outside wall, ideally in a room
where noise does not matter, in order to eliminate
noise problems. If this is not possible, avoid placing
it against a wall behind a bedroom or other room
where noise may be a problem.
• Wherever the unit is located, walls to sound sensitive
rooms should be fitted with sound insulation.
• Condensation comes from the underside of the vent-
ilation heat exchanger. Condensation outlet with water
seal must be installed and routed to an internal drain.
• The ventilation heat exchanger’s installation area
should always have a temperature of at least 10 °C
and max. 35 °C.
INSTALLATION AREA
Leave a free space of 1,000 mm in front of the distribu-
tion box and 200 mm in front of the other sides. Because
servicing is carried out from underneath, free space of
1,600 mm is recommended below the unit.
1000
200
200
200
7
Chapter 2 | Delivery and handling
NIBE GV-HR 130
2 Delivery and handling