Nibe FIGHTER 1150 Maintenance Instruction Download Page 3

FIGHTER 1150/1250

A B

I II III

I II

I II

5 0 . 0     C

V a r m v a t t e n t e m p .   1 . 0

A B

A B

I II III

I II

5 0 . 0     C

V a r m v a t t e n t e m p e r a t u r  

13.43

1.0

P

A B

I II III

I II

5 0 . 0     C

 

13.43

1.0

P

Left keypad

Operating mode

This button is used to set the required op-
erating mode with regard to permitting/
blocking the circulation pump and additional 
energy. The change does not need to be 
confirmed with the enter button.

The different operating modes are:

Auto mode:

 FIGHTER 1150/1250 automatically selects the 

operating mode by taking the outdoor temperature into 
account. The circulation pump and the immersion heater 
are permitted to run as needed.

Summer mode:

 Only production of hot water using 

FIGHTER 1150/1250. The circulation pump and immersion 
heater are blocked. However, when “Extra hot water” is 
activated the immersion heater is connected.

Spring/Autumn mode:

 Production of heating and hot 

water using FIGHTER 1150/1250. The circulation pump is 
operational. The immersion heater is disabled. However, 
when “Extra hot water” is activated the immersion heater 
is connected.

The current operating mode is shown on the display when 
the button is pressed and the mode changes when you 
continue to press the button. The display returns to the 
normal display mode once the enter button is pressed.

Alarmmode:

 In alarm mode the operating mode changes 

to winter mode and additional heat engages. The alarm 
mode blocks hot water charging to draw attention to the 
alarm.
 

Extra hot water 

The “Extra hot water” function is activated 
using this button. The change does not need 
to be confirmed with the enter button.

A:

 Means that the hot water temperature is increased to 

60 °C (adjustable). The temperature then returns to the 
normal value.
When 

A

 comes on the function is activated.

When 

A

 goes out the function is deactivated.

Press once to give extra hot water for 3 hours.
Press twice to give extra hot water for 6 hours.
Press three times to give extra hot water for 12 hours.
Press four times to give extra hot water for 24 hours.
Press five times to deactivate the function.

Explanation

Heating curve offset

Changing the room temperature manually.

If you want to temporarily or permanently lower or raise 
the indoor temperature relative to the previously set 
temperature, turn the “Heating curve offset” knob anti-
clockwise or clockwise. One up to three scale markings 
correspond to a change of about one degree in the room 
temperature. 

NOTE!

 An increase in the room temperature may be “in-

hibited” by the radiator or floor heating thermostats, if so 
these must be turned up.

Heating curve offset

Right keypad

Plus button

This button is used to scroll through the 
menu system (forwards) or increase the 
value of the selected parameter.
See the section “Control - General”.

Minus button

This button is used to scroll through the 
menu system (backwards) or lower the value 
of the selected parameter.
See the section “Control - General”.

Enter button

This button is used to select a lower menu 
in the menu system, to activate a param-
eter change as well as confirm a parameter 
change.