background image

RANGE OF SERVICES

myUplink gives you access to various levels of service. The
base level is included and, apart from this, you can choose
two premium services for a fixed annual fee (the fee varies
depending on the functions selected).

Premium

change set-

tings

Premiumex-

tended his-

tory

Basic

Service level

X

X

X

Viewer

X

X

X

Alarm

X

X

X

History

-

X

-

Extended history

X

-

-

Manage

MOBILE APPS FOR MYUPLINK

The mobile apps can be downloaded free of charge from
where you usually download your mobile apps. Logging into
the mobile app is performed using the same account details
as on

myuplink.com

.

NIBE SMART PRICE ADAPTION™

Smart Price Adaption is not available in all countries.
Contact your NIBE dealer for more information.

Smart Price Adaption adjusts the heat pump's

consumption according to the time of day that electricity
prices are lowest. This allows for savings, provided that the
hourly rate subscription has been signed with the electricity
supplier.

The function is based on hourly rates for the coming day
being downloaded via myUplink. To use the function, an In-
ternet connection and account on myUplink are necessary.

SMART HOME

When you have a smart home system that can communicate
with myUplink, you can control the installation via an app
by activating the "smart home" function.

By allowing connected units to communicate with myUplink,
your heating system becomes a natural part of your
homesmart home and gives you the opportunity to optimise
the operation.

Remember that the “smart home” function requires myUplink
in order to work.

NIBE SMART ENERGY SOURCE™

Smart Energy Source™ prioritises how / to what
extent each docked energy source will be used.
Here you can choose if the system is to use the
energy source that is cheapest at the time. You can

also choose if the system is to use the energy source that
is most carbon neutral at the time.

14 NIBE F2120

Summary of Contents for F2120-16

Page 1: ...the noise level stays low NIBE F2120 has three phase connection which simplifies electrical installation Thanks to smart technology the product gives you control over your energy consumption and will...

Page 2: ...mplete with a smart and user friendly control system hot water heater addition al heat self regulating circulation pump etc The control modules SMO offer a flexible system solution that can be easily...

Page 3: ...0 Stainless steel 3x230 V Part no 069 201 VVM S320 Stainless steel 3x400 V Part no 069 196 APH APH VVM 310 Stainless steel 3x400 V With integrated EMK 310 Part no 069 084 VVM 310 Stainless steel 3x400...

Page 4: ...ns SYMBOL KEY Meaning Symbol Shut off valve Tapping valve Non return valve Circulation pump Expansion vessel Filterball Pressure gauge P Safety valve Trim valve Reversing valve shunt Control module Ai...

Page 5: ...to the base requires four persons one for each lifting strap Installation and positioning Place F2120 outdoors on a solid level base that can take the weight preferably a concrete foundation If concre...

Page 6: ...n front must be at least 1 000 mm for any future servicing 350 mm Fritt utrymme bakom Fritt utrymme framf r dock 1000 mm f r ev framtida service Min avst nd vid anv ndning av flera F2300 600 mm 1000 m...

Page 7: ...ponents Local differences in the enclosed kit may occur See relevant installer manual for more information F2120 16 F2120 20 Filterball G1 1 4 LEK LEK 2 x flexible pipes DN25 G1 1 4 with 4 x gaskets N...

Page 8: ...tion of the pipe that can be affected by frost must be heated by the heating cable to prevent freezing Pipe with heating cable for draining the condensation water trough is not included To ensure the...

Page 9: ...men sion mm Minimum re commended pipe dimen sion DN Minimum flow duringdefrost ing 100 pump speed l s Air water heat pump 28 25 0 38 F2120 16 3x400V 35 32 0 48 F2120 20 3x400V An undersized system can...

Page 10: ...h both the climate system and the hot water heater trim valve When connecting to control module and hot water heater Vent the heat pump by the heating medium supply con nection XL1 using the venting n...

Page 11: ...20 must be installed via an isolator switch The cable area has to be dimensioned based on the fuse rating used The RCD should have a nominal tripping current of no more than 30 mA The incoming supply...

Page 12: ...re free from dirt and leaves Regularly check that condensation is routed away correctly through the condensation pipe Ask your installer for assist ance if required KEEP FREE OF SNOW AND ICE F2120 F21...

Page 13: ...her hot water demand there is a function called More hot water For temporary higher hot water demand there is a function that allows the temperature to be raised temporarily for up to 12 hours or by a...

Page 14: ...owest This allows for savings provided that the hourly rate subscription has been signed with the electricity supplier The function is based on hourly rates for the coming day being downloaded via myU...

Page 15: ...Dimensions F2120 F2120 1280 1205 40 52 65 85 470 35 65 1130 180 475 70 110 612 40 NIBE F2120 15 Technical data...

Page 16: ...nsitive neigh bouring area The sound pressure levels are further affected by walls bricks differences in ground level etc and should therefore only be seen as guide values 2 m 6 m 10 m LEK 20 16 F2120...

Page 17: ...the heating medium is allowed to be lower for a short period e g at start up POWERDURINGHEATINGOPERATIONANDCOP Maximum capacity during continuous operation Defrosting is not included F2120 16 2 4 6 8...

Page 18: ...C Supply temperature 55 C COP POWER DURING COOLING OPERATION F2120 16 2 0 3 0 4 0 5 0 6 0 10 0 9 0 8 0 7 0 15 20 25 30 35 40 45 Utomhustemperatur C F2120 16 Max och min kylningskapacitet Kylningskapac...

Page 19: ...rant circuit R410A Type of refrigerant 2088 GWP refrigerant 3 0 kg Volume Scroll Type of compressor 6 26 t CO2 equivalent The cooling circuit is hermetically sealed Airflow 4 500 4 150 m3 h Max airflo...

Page 20: ...ssories list available at nibe eu Not all accessories are available on all markets Condensation water pipe Condensation water pipe different lengths LEK KVR 11 10 1 metres Part no 067 823 KVR 11 30 3...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...r climate that allows us to enjoy a comfortable life whatever the weather Our extensive range of products supply your home with cooling heating ventilation and hot water making it possible for you to...

Reviews: