External heating cable KVR 10 (Accessory)
F2040 is equipped with a plinth for external heating
cable EB14 not supplied). The connection is fused with
250 mA (F3 on the communication board AA23). If
another cable is to be used, the fuse must be replaced
with a suitable one (see table).
NOTE
Self regulating heating cables must not be
connected.
NIBE Part no.
Fuse
Fuse (F3)
Total
power
(W)
Length
(m)
718085
T100mA/250V
15
1
518900*
T250mA/250V
45
3
718086
T500mA/250V
90
6
* Fitted at the factory.
Connect external heating cable (EB14) to terminal block
X1:4–6 according to following image:
5
6
4
2
3
1
External
F2040
X1
EB14
External heat cable
AA23
F3
NOTE
The pipe must be able to withstand the heat
from the heating cable.
To ensure this function the accessory KVR 10
should be used.
Cable routing
The following images show recommended cable rout-
ing from the distribution box to the condensation water
pipe. Route the heating cable (EB14) through the
grommet underneath and secure with two cable ties
at the electrical connection. Transfer between electrical
cable and heating cable must occur after the lead-in
to the condensation water pipe.
F2040-8
LEK
Heating cable (EB14)
Secure the heating
cable (EB14) here
using two cable ties.
NIBE™ F2040
Chapter 5 |
Electrical connections
28
Summary of Contents for F2040 Series
Page 1: ...Installer manual LEK LEK LEK NIBE F2040 8 12 16 kW Air water heat pump IHB GB 1512 3 231844...
Page 2: ......
Page 55: ...Electrical circuit diagram F2040 8 53 Chapter 11 Technical data NIBE F2040...
Page 57: ...F2040 12 55 Chapter 11 Technical data NIBE F2040...
Page 59: ...F2040 16 57 Chapter 11 Technical data NIBE F2040...
Page 62: ......
Page 63: ......
Page 64: ...231844 NIBE AB Sweden Hannabadsv gen 5 Box 14 SE 285 21 Markaryd info nibe se www nibe eu...