Transport and storage
F2040 must be transported and stored vertically.
Assembly
■
Place F2040 outdoors on a solid level base that can
take the weight, preferably a concrete foundation. If
concrete slabs are used they must rest on asphalt or
shingle.
■
The concrete foundation or slabs must be positioned
so that the lower edge of the evaporator is at the level
of the average local snow depth, although a minimum
of 300 mm.
■
The F2040 should not be positioned next to sensitive
walls, for example, next to a bedroom.
■
Also ensure that the placement does not inconveni-
ence the neighbours.
■
F2040 must not be placed so that recirculation of the
outdoor air can occur. This causes lower output and
impaired efficiency.
■
The evaporator should be sheltered from direct wind,
which negatively affects the defrosting function. Place
F2040 protected from wind against the evaporator.
■
Large amounts of condensation water, as well as melt
water from defrosting, may be produced. Condensa-
tion water must be led off to a drain or similar (see
page 8.
■
Care must be exercised so that the heat pump is not
scratched during installation.
LEK
LEK
LEK
Cirka 1 m
LEK
LEK
LEK
Cirka 1 m
min 300 mm
Min. 300 mm
Do not place F2040 directly on the lawn or other non
solid surface.
If there is a risk of snow slip from roof, a protective roof
or cover must be erected to protect the heat pump, pipes
and wiring.
Installation area
The distance between F2040 and the house wall must
be at least 150 mm. Clearance in front of F2040 should
be at least one metre.
50
255
Ställbar 40-50
955
243
512
110
395
265
50
452
1075
1145
108
Ø40*
14
85
3000 mm
400 mm
Minimalt
fritt utrymme
Minimalt
fritt utrymme
Fritt utrymme
framför
150 mm
Fritt
utrymme
bakom
600mm
Minimum
free space
Minimum
free space
Free
space
behind
400 mm
600 mm
150 mm
3000 mm
Free space
in front
7
Chapter 2 |
Delivery and handling
F2040
2 Delivery and handling
Summary of Contents for F2040-12
Page 1: ...Installer manual LEK LEK LEK UN F2040 6 8 12 16 Air water heat pump IHB EN 1746 6 231844 ...
Page 2: ......
Page 47: ...Connection to board AA23 BP4 BT15 BT12 BT3 AA23 S3 47 Chapter 8 Disturbances in comfort F2040 ...
Page 74: ...F2040 Chapter 11 Technical data 74 ...