Troubleshooting
NOTE
Work behind covers secured by screws may
only be carried out by, or under the supervision
of, a qualified installation engineer.
NOTE
As F2040 can be connected to a large number
of external units, these should also be checked.
NOTE
In the event of action to rectify malfunctions
that require work within screwed hatches the
incoming electricity must isolated at the safety
switch.
NOTE
Alarms are acknowledged on the indoor mod-
ule / control module (VVM / SMO).
The following tips can be used to rectify comfort disrup-
tion:
Basic actions
First and foremost
Start by checking any alarm messages in the info menu
on the indoor module (VVM) / control module (SMO).
Follow the instructions on the display on the indoor
module (VVM) / control module (SMO).
F2040 not in operation
F2040 communicates all alarms to the indoor mod-
ule/control module (VVM / SMO).
■
Ensure that the F2040 is connected to the power
source and that compressor operation is required.
■
Check the indoor module/control module (VVM /
SMO). See section "Disturbances in comfort" in the In-
staller Manual for the indoor module/control module
(VVM / SMO).
F2040 does not communicate
■
Check that the addressing of F2040 is correct.
■
Check that the communication cable is correctly con-
nected and working.
Further possible measures
If any components are disconnected from the power.
Start by checking the following items:
■
That the heat pump is running or that the supply cable
to F2040 is connected.
■
Group and main fuses of the accommodation.
■
The property's earth circuit breaker.
■
The heat pump’s fuse (F).
Low hot water temperature or a lack of hot
water
NOTE
The hot water is always set on the indoor
module (VVM) or the control module (SMO).
This part of the fault-tracing chapter only applies if the
heat pump is docked to the hot water heater.
■
Large hot water consumption.
–
Wait until the hot water has heated up.
■
The hot water settings are adjusted on the display on
the indoor module / control module.
–
See the manual for the indoor module or control
module.
■
Clogged particle filter.
–
Check whether alarm "high condenser out" (162) is
an information message. Check and clean the
particle filter.
Low room temperature
■
Closed thermostats in several rooms.
–
Set the thermostats to max in as many rooms as
possible.
■
Incorrect settings in indoor module or control module.
–
See the manual for the indoor module / control
module (VVM / SMO).
■
Incorrect flow across the heat pump.
–
Check whether alarm "high condenser in" (163) or
"high condenser out" (162) are info messages. Follow
the instructions for adjusting charge flow.
High room temperature
■
Incorrect settings in indoor module or control module.
–
See the manual for the indoor module or control
module.
Large amount of water below F2040
Check that the water drainage via the condensation pipe
(KVR 10) is working.
F2040
Chapter 8 |
Disturbances in comfort
44
8 Disturbances in comfort
Summary of Contents for F2040-12
Page 1: ...Installer manual LEK LEK LEK UN F2040 6 8 12 16 Air water heat pump IHB EN 1746 6 231844 ...
Page 2: ......
Page 47: ...Connection to board AA23 BP4 BT15 BT12 BT3 AA23 S3 47 Chapter 8 Disturbances in comfort F2040 ...
Page 74: ...F2040 Chapter 11 Technical data 74 ...
Page 77: ...F2040 12 77 Chapter 11 Technical data F2040 ...