Night cooling during heating:
It is possible to have night
cooling during the time heating is permitted.
Caution
Night cooling can only be used when heating
is not permitted; does not apply when "Recov-
ery stop during heating" is selected (see menu
1.2.7).
MENU 1.2.5 - FAN RETURN TIME
speed 1 – speed 4
Setting range: 1 – 24 h
Here, you select the return time for the temporary speed
change (speed 1 – speed 4) of the ventilation in menu
1.2.1.
Return time is the time taken before the ventilation
speed returns to normal speed.
MENU 1.2.6 - FILTER CLEANING INTERVAL
Months between filter cleaning
Setting range: 1 – 24 months
The filters in ERS S10 are of a type that should not be
cleaned, they have to be replaced instead. These must
be replaced regularly; how often depends e.g. on the
amount of dust in the ventilation air. Test to find out
what is most appropriate for your installation.
Set the interval for the reminder in this menu.
The menu shows the time remaining until the next re-
minder, and you can also reset active reminders.
MENU 1.2.7 - VENTILATION RECOVERY
Temp stop of heat recovery
Setting range: 5 – 30 °C
Min. diff. ind. temp. - outd. temp.
Setting range: 2 – 10 °C
Recovery stop during heating
Setting range: on/off
Cooling recovery
Setting range: on/off
St temp sup air cooled by exh air
Setting range: -20.0 – 41.0 °C
Min diff outd and exhaust air
Setting range: 3.0 – 10.0 °C
When there is no heating demand, and the outdoor
temperature is approaching the indoor temperature,
heat recovery is stopped to prevent the house from
being heated further.
Caution
Only the heat recovery is stopped, not the
ventilation.
Temp stop of heat recovery
: Here, you set the outside
temperature at which ventilation recovery is to stop.
Min. diff. ind. temp. - outd. temp.
: Here, you set the
temperature difference between the indoor air and the
outdoor air that is required in order for ventilation recov-
ery to start.
Recovery stop during heating
: Stopping ventilation re-
covery during the time heating is permitted is possible.
Cooling recovery:
When there is no heating demand,
ventilation recovery is stopped to prevent the house
from being heated further. When it is warm indoors and
even warmer outdoors, ERS S10 can be used to prevent
the house from heating up more than necessary. During
cooling recovery, the cooler air from the house is used
to cool the incoming air.
"Cooling recovery" is started when the exhaust air tem-
perature is a certain number of degrees below the out-
door temperature and it is warm outside.
St temp sup air cooled by exh air:
Here, you set the
outdoor temperature at which cooling recovery will start.
Caution
"St temp sup air cooled by exh air" cannot be
lower than "Stop heating" in menu 7.1.10.2 –
"Auto mode setting".
Min diff outd and exhaust air:
Here, you set the temper-
ature difference between outdoor air and exhaust air
that is required in order for cooling recovery to start.
MENU 7.1.4.1 - FAN SPEED, EXHAUST AIR
Normal and Fan speed 1 – Fan speed 4
Setting range: 0 – 100 %
Set the speed for the five different selectable speeds
for the fan here.
MENU 7.1.4.2 - FAN SPEED, SUPPLY AIR
Normal and Fan speed 1 – Fan speed 4
Setting range: 0 – 100%
Set the speed for the five different selectable speeds
for the fan here.
19
Chapter 7 | Program settings
NIBE ERS S10-400