background image

Program setting the ELK 15 can be performed via the start
guide or directly in the menu system in your compatible heat
pump/indoor module.

Caution

Also see the Installer manual for the product that
ELK 15 will be connected to.

The start guide appears at the first start-up after installation,
but can also be found in menu 7.7 in the S-series and 5.7 in
the F-Series.

Menu system

S-SERIES

SMO S40, S1155, S1255, VVM S320

Information about menu settings for the above products
can be found in the manual for AXC 40 or in the main
product’s manual.

Menu 7.2.1 - Add/remove accessories

Add or remove accessories here.

Select "Step-controlled additional heat".

Menu 7.2.6 - Step-controlled additional heat

(AXC)

Here you can perform the following settings:

Select when the addition is to start.

Set max permitted number of additional steps.

If binary stepping is to be used.

Caution

"Start additional heat" in the menus 7.2.6 (external
step-controlled additional heat) and 7.1.10.3 (de-
gree minute settings internal additional heat) are
factory set at 400DM. If both of the additional heat
options are used and you want to have more steps,
the start difference needs to be changed in one
of the menus.

Menu 7.5.3 - Forced control

Forced control of the various components in the main
product and of any connected accessories.

EB1-AA5-K4: Activating the circulation pump (GP10).

EB1-AA5-K1: Activating additional step 1.

EB1-AA5-K2: Activating additional step 2.

Setting of 0–10 V stepless forced control.

See the ”General” section on page17 to see which accessory
is required for your product.

F-SERIES

F1345, F1355, SMO 20 and SMO 40

Menu 4.9.3 - degree minute setting

Here you select when the additional heat is to start and the
degree minute intervals.

Menu 5.1.12 - addition

add. heat in tank

Setting range: on/off

Factory setting, fuse: off

max step

Setting range (binary stepping deactivated): 0 – 3

Setting range (binary stepping activated): 0 – 7

Default value: 3

fuse size

Setting range: 1 - 400 A

Factory setting: 16 A

transformation ratio

Setting range: 300 - 2500

Factory setting: 300

Here, you select whether the step-controlled additional heat
is placed before or after the reversing valve for hot water
charging (QN10). Step-controlled additional heat could be,
for example, an external electric boiler.

Here you can set the max permitted number of additional
heat steps and binary or linear stepping. When binary step-
ping is deactivated (off), the settings refer to linear stepping.

If the hot water accessory is available and additional heat
location is selected as "after QN10" and additional heat in
the tank is selected, the number of steps are restricted to
2 steps linear or 3 steps binary. Output AA7-X2:6 is reserved
in this mode for additional heat in the hot water tank.

You can also set the fuse size.

TIP

See the accessory installation instructions for
function description.

Menu 5.2 - system settings

Activating/deactivating of accessories.

Select: "step controlled add. heat".

Menu 5.3.6 - step controlled add. heat

Here you can perform the following settings:

Select when the addition is to start.

Set max permitted number of additional steps.

If binary stepping is to be used.

23

Kapitel 5 | Program settings

NIBE ELK 15

Summary of Contents for ELK 15

Page 1: ...Installat rshandbok NIBE ELK 15 Installat rshandbok Elkassett SE Installer Manual Electric heater GB Installateurhandbuch Elektroheizpatrone DE Asennusohje S hk vastus FI IHB SV 2205 13 331546...

Page 2: ......

Page 3: ...ing av tappvatten Symboler OBS Denna symbol betyder fara f r m nniska eller ma skin T NK P Vid denna symbol finns viktig information om vad du ska t nka p n r du installerar eller servar an l ggningen...

Page 4: ...glera effekten Kompatibla produkter Beroende p vilken produkt ELK 15 ska anv ndas mot ser inkopplingen ut p olika s tt Dessa produkter kan kopplas in direkt till ELK 15 SMO 20 SMO 40 SMO S40 F1345 F13...

Page 5: ...EB1 Temperaturbegr nsare FQ10 Anslutningsplint X1 Kontaktor 5 0 kW K1 QA1 Kontaktor 10 0 kW K2 QA2 Reservl gestermostat BT30 Anslutning framledning G 32 XL1 Anslutning returledning G 32 XL2 Kabelgenom...

Page 6: ...ionens l gsta punkt Kvarvarande vatten i ELK 15 t ms genom returledningsanslutning XL2 se Komponentplacering p sida 5 Anv nds returledningsan slutningen p ELK 15 normalt f r avtappning av anl ggningen...

Page 7: ...plintarnas h gra sida enligt bild LEK F1345 2 0 F1355 Plint X1 i ELK 15 ansluts till plintarna X5 X7 och X8 p ing ngs kortet AA101 i v rmepumpen enligt bild X5 X7 X8 X4 1 2 3 AA101 3 1 2 3 4 5 6 7 8 9...

Page 8: ...X4 X3 ELK 15 V rmepump SMO S40 J 1 1 J 1 2 J 2 2 7 8 5 6 X1 Styrmodul ELK 15 1 2 3 C L L L L N N N N N N N AA100 X3 AA100 X4 AA100 X8 4 ELK 15 Styrmodul SMO 20 och SMO 40 Plint X1 i ELK 15 ansluts ti...

Page 9: ...et enligt bild J 1 1 J 1 2 J 2 2 7 8 5 6 4 X1 Tillbeh rskort ELK 15 2 3 4 7 5 6 8 9 AA5 X9 Tillbeh rskort ELK 15 F1145 F1155 F1245 F1255 VVM 225 VVM 310 VVM 320 VVM 325 och VVM 500 F r inkoppling av E...

Page 10: ...eny 4 9 3 gradminutinst llning H r v ljer du n r tillsatsen ska starta och gradminuter mellan stegen Meny 5 1 12 tillsats tillsats i tank Inst llningsomr de on off Fabriksinst llning s kring off max s...

Page 11: ...exempelvis g ra f ljande inst llningar V lja n r tillsatsen ska starta St lla in max antal till tna tillsatssteg Om bin r stegning ska anv ndas T NK P start tillsats i menyerna 5 3 6 extern stegstyrd...

Page 12: ...300 90 140 60 560 30 240 135 65 NIBE ELK 15 Kapitel 6 Tekniska uppgifter 12...

Page 13: ...5 liter Volym vrigt SIS 2348 EN 1 4404 Material elpatron SIS 2348 EN 1 4404 Material tub Bly i m ssingsdetaljer mnen enligt f rordning EG nr 1907 2006 artikel 33 Reach 624 07 87 RSK nr 069 022 Art nr...

Page 14: ...nominell avgiven v rmeeffekt och h gtem peraturdrift 1 Vid 30 av nominell avgiven v rmeeffekt och l gtemperaturdrift kW P1 Vid 30 av nominell avgiven v rmeeffekt och l gtemperaturdrift vriga poster Ti...

Page 15: ...pecification Sheet 050888 2 Page 2 2 Created 2019 03 08 07 49 0 001 GBN 2019 03 08 Production ASN 2015 02 10 400V 3 50Hz 15KW WIRING DIAGRAM ELK15 ELSCHEMA ELK15 050888 2 15 Kapitel 6 Tekniska uppgift...

Page 16: ...he fuse rating used ELK 15 must not be used for heating tap water Symbols NOTE This symbol indicates danger to person or machine Caution This symbol indicates important information about what you shou...

Page 17: ...control of the power Compatible products Connection is different depending on which product ELK 15 is to be used with These products can be connected directly to ELK 15 SMO 20 SMO 40 SMO S40 F1345 F1...

Page 18: ...er EB1 Temperature limiter FQ10 Terminal block X1 Contactor 5 0 kW K1 QA1 Contactor 10 0 kW K2 QA2 Emergency mode thermostat BT30 Connection supply line G 32 XL1 Connection return line G 32 XL2 Cable...

Page 19: ...point on the pipe installation The remain ing water in ELK 15 is drained through the return line connec tion XL2 see Component location on page 18 If the re turn line connection on ELK 15 is normally...

Page 20: ...hand side of the termin al block as illustrated LEK F1345 2 0 F1355 Terminal block X1 on ELK 15 is connected to terminal blocks X5 X7 and X8 on the input board AA101 in the heat pump as illustrated X5...

Page 21: ...4 5 6 2 3 1 X2 X4 X3 ELK 15 Heat pump SMO S40 J 1 1 J 1 2 J 2 2 7 8 5 6 X1 Styrmodul ELK 15 1 2 3 C L L L L N N N N N N N AA100 X3 AA100 X4 AA100 X8 4 ELK 15 Control module SMO 20 and SMO 40 Terminal...

Page 22: ...on the accessory board as illustrated J 1 1 J 1 2 J 2 2 7 8 5 6 4 X1 Tillbeh rskort ELK 15 2 3 4 7 5 6 8 9 AA5 X9 Accessory card ELK 15 F1145 F1155 F1245 F1255 VVM 225 VVM 310 VVM 320 VVM 325 and VVM...

Page 23: ...eral section on page17 to see which accessory is required for your product F SERIES F1345 F1355 SMO 20 and SMO 40 Menu 4 9 3 degree minute setting Here you select when the additional heat is to start...

Page 24: ...settings Activating deactivating of accessories Select step controlled add heat Menu 5 3 6 step controlled add heat Here you can perform the following settings Select when the addition is to start Se...

Page 25: ...300 90 140 60 560 30 240 135 65 25 Kapitel 6 Technical data NIBE ELK 15...

Page 26: ...boiler Yes No B11 boiler Yes No Cogeneration space heater Yes No Combination heater 36 7 s Seasonal space heating energy efficiency kW 15 Prated Rated heat output Forboilerspaceheatersandboilercombina...

Page 27: ...gram Part Specification Sheet 050888 2 Page 2 2 Created 2019 03 08 07 49 0 001 GBN 2019 03 08 Production ASN 2015 02 10 400V 3 50Hz 15KW WIRING DIAGRAM ELK15 ELSCHEMA ELK15 050888 2 27 Kapitel 6 Techn...

Page 28: ...nicht zur Brauchwasserberei tung verwendet werden Symbole HINWEIS Dieses Symbol kennzeichnet eine Gefahr f r Per sonen und Maschinen ACHTUNG Dieses Symbol verweist auf wichtige Angaben dazu was bei I...

Page 29: ...xternen Leistungsregelung Kompatible Produkte Je nach Produkt mit dem ELK 15 verwendet werden soll erfolgt der Anschluss auf unterschiedliche Weise Diese Produkte k nnen direkt mit ELK 15 verbunden we...

Page 30: ...Heizpatrone EB1 Temperaturbegrenzer FQ10 Anschlussklemme X1 Sch tz 5 0 kW K1 QA1 Sch tz 10 0 kW K2 QA2 Notbetriebsthermostat BT30 Anschluss Vorlauf G 32 XL1 Anschluss R cklauf G 32 XL2 Kabeldurchf hr...

Page 31: ...fsten Punkt der Rohrinstallation ein Entleerungsventil angebracht wird Verbleibendes Wasser in ELK 15 wird ber den R cklaufanschluss XL2 entleert siehe Position der Komponenten auf Seite 30 Wird der R...

Page 32: ...ob sich die Bezeichnung 2 0 rechts ber den Anschlussklemmen befindet siehe Abbildung LEK F1345 2 0 F1355 Anschlussklemme X1 in ELK 15 wird mit den Anschlussklem men X5 X7 und X8 an der Eingangsplatin...

Page 33: ...1 J 1 2 J 2 2 7 8 5 6 4 X1 F1345 ELK 15 6 7 8 9 5 2 3 1 4 5 6 2 3 1 X2 X4 X3 ELK 15 W rmepumpe SMO S40 J 1 1 J 1 2 J 2 2 7 8 5 6 X1 Styrmodul ELK 15 1 2 3 C L L L L N N N N N N N AA100 X3 AA100 X4 AA1...

Page 34: ...1 in ELK 15 wird mit Anschlussklemme X9 an der Zubeh rkarte verbunden siehe Abbildung J 1 1 J 1 2 J 2 2 7 8 5 6 4 X1 Tillbeh rskort ELK 15 2 3 4 7 5 6 8 9 AA5 X9 Zubeh rplatine ELK 15 F1145 F1155 F124...

Page 35: ...eines auf Seite 29 f r erforderliches Zubeh r f r Ihr Produkt F SERIE F1345 F1355 SMO 20 und SMO 40 Men 4 9 3 Gradminuteneinstellung Hier legen Sie fest wann die Zusatzheizung starten soll und welche...

Page 36: ...ktivierung Deaktivierung von Zubeh r W hlen Sie stufengereg ZH Men 5 3 6 stufengereg ZH Hier k nnen Sie z B folgende Einstellungen vornehmen Legen Sie fest wann die Zusatzheizung starten soll StellenS...

Page 37: ...300 90 140 60 560 30 240 135 65 37 Kapitel 6 Technische Daten NIBE ELK 15...

Page 38: ...he 11 kg Gewicht 4 5 l Volumen Sonstiges SIS 2348 EN 1 4404 Material Heizpatrone SIS 2348 EN 1 4404 Material Rohr Blei in Messingbauteilen Stoffe gem Verordnung EG Nr 1907 2006 Artikel 33 Reach 069 02...

Page 39: ...15 P4 Bei abgegebener Nennheizleistung und Hochtemperaturbetrieb 1 Bei 30 der abgegebenen Nennheizleistung und Niedrigtemperaturbetrieb kW P1 Bei 30 der abgegebenen Nennheizleistung und Niedrigtempera...

Page 40: ...Specification Sheet 050888 2 Page 2 2 Created 2019 03 08 07 49 0 001 GBN 2019 03 08 Production ASN 2015 02 10 400V 3 50Hz 15KW WIRING DIAGRAM ELK15 ELSCHEMA ELK15 050888 2 NIBE ELK 15 Kapitel 6 Techn...

Page 41: ...ei tule k ytt k ytt veden l mmi tykseen Symbolit HUOM T m symboli merkitsee ihmist tai konetta uhkaa vaa vaaraa MUISTA T m symboli osoittaa t rke n tiedon joka pit ottaa huomioon laitteistoa asennetta...

Page 42: ...ntaktorit tehon ohjaamiseen Yhteensopivat tuotteet Liit nt tapa riippuu siit mihin tuotteeseen ELK 15 liitet n N m tuotteet voidaan kytke suoraan ELK 15 een SMO 20 SMO 40 SMO S40 F1345 F1355 N m tuott...

Page 43: ...o S hk vastus EB1 L mp tilarajoitin FQ10 Liitinrima X1 Kontaktori 5 0 kW K1 QA1 Kontaktori 10 0 kW K2 QA2 Varatilatermostaatti BT30 Liit nt menojohto G 32 XL1 Liit nt paluujohto G 32 XL2 Kaapelil pivi...

Page 44: ...limpaan pisteeseen ELK 15 n j ljelle j nyt vesi tyhjennet n paluuliit nn n XL2 kautta katso Kom ponenttien sijainti sivulla 43 Jos j rjestelm tyhjennet n tavallisesti ELK 15 n paluuliit nn n kautta si...

Page 45: ...1345 2 0 F1355 Liitin X1 ELK 15 ssa kytket n l mp pumpun tulokortin AA101 liittimiin X5 X7 ja X8 kuvan mukaisesti X5 X7 X8 X4 1 2 3 AA101 3 1 2 3 4 5 6 7 8 9 X5 1 2 3 4 5 6 7 8 9 X6 X7 X8 X9 FC1 AA101...

Page 46: ...3 1 4 5 6 2 3 1 X2 X4 X3 ELK 15 L mp pumppu SMO S40 J 1 1 J 1 2 J 2 2 7 8 5 6 X1 Styrmodul ELK 15 1 2 3 C L L L L N N N N N N N AA100 X3 AA100 X4 AA100 X8 4 ELK 15 Ohjausyksikk SMO 20 ja SMO 40 Liiti...

Page 47: ...tin liittimeen X9 kuvan mukaisesti J 1 1 J 1 2 J 2 2 7 8 5 6 4 X1 Tillbeh rskort ELK 15 2 3 4 7 5 6 8 9 AA5 X9 Lis varustekortti ELK 15 F1145 F1155 F1245 F1255 VVM 225 VVM 310 VVM 320 VVM 325 ja VVM 5...

Page 48: ...ukset Katso luvusta Yleist sivulla 42 tuotetta varten tarvittavat lis varusteet F SARJA F1345 F1355 SMO 20 ja SMO 40 Valikko 4 9 3 asteminuuttiasetukset T ss valitset milloin lis l mm nl hteen tulee k...

Page 49: ...asetukset Lis varusteiden aktivointi deaktivointi Valitse porrasohjattu lis l mp Valikko 5 3 6 porrasohjattu lis l mp T ll voit tehd seuraavat asetukset Valitse milloin lis l mm nl hteen tulee k ynnis...

Page 50: ...300 90 140 60 560 30 240 135 65 NIBE ELK 15 Kapitel 6 Tekniset tiedot 50...

Page 51: ...mmityksen kausikeskihy tysuhde kW 15 Prated Nimellinen antol mmitysteho Kattiloille keskusl mmityksell ja kattiloille sis nrakennetulla k ytt vesil mmityksell nettohy tysuhde Kattiloille keskusl mmity...

Page 52: ...Part Specification Sheet 050888 2 Page 2 2 Created 2019 03 08 07 49 0 001 GBN 2019 03 08 Production ASN 2015 02 10 400V 3 50Hz 15KW WIRING DIAGRAM ELK15 ELSCHEMA ELK15 050888 2 NIBE ELK 15 Kapitel 6...

Page 53: ...Part Specification Sheet 050888 2 Page 2 2 Created 2019 03 08 07 49 0 001 GBN 2019 03 08 Production ASN 2015 02 10 400V 3 50Hz 15KW WIRING DIAGRAM ELK15 ELSCHEMA ELK15 050888 2 53 Kapitel NIBE ELK 15...

Page 54: ......

Page 55: ...NORWAY NETHERLANDS GREAT BRITAIN ABK Qviller AS Brobekkveien 80 0582 Oslo Tel 47 23 17 05 20 post abkqviller no nibe no NIBE Energietechniek B V Energieweg 31 4906 CG Oosterhout Tel 31 0 168 47 77 22...

Page 56: ...ion fr n NIBE Energy Systems Alla produktillustrationer fakta och data bygger p aktuell information vid tidpunkten f r publikationens godk nnande NIBE Energy Systems reserverar sig f r eventuella fakt...

Reviews: