GB
16
!
The minimum distance in front of
the stove opening to combustible
parts of the building or interior
decoration must be at least 1,1 m.
The dimension diagrams only
show the minimum permitted
installation distances for the
stove. When connecting to a steel
flue, also note the safety distance
requirements of the flue. The
safety distance between an un-
insulated flue and a combustible
part of the building should be at
least 450 mm.
Installation distances
WHEN INSTALLING TURNTABLE (OPTION)
the following
installation distances do not apply.
See the separate turntable installation instructions.
A = height from floor to chimney
connection upwards
B = height from floor to c/c chimney
connection rear
C = height from floor to air inlet
D = height from floor to lower edge
of hatch
A separate glass hearth
plate (accessory)
increases the connection
height to the chimney by
10 mm.
Permitted area for
combustible parts
of the building
* If the stove is placed on a hearth plate made of glass for example (accessory), the height from the floor is affected by a distance corresponding to the thickness of the hearth plate, for a free standing
glass hearth plate this is 10 mm.
** To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.
INSTALLATION AGAINST COMBUSTIBLE WALLS
INSTALLATION AGAINST FIREWALLS
C856 / C856G Style
465
950
2000
93
192
D 254
Combustible roof
365
183
A 905*
113
B 816*
46
C 270
Ø150
Air inlet Ø67
200
432
663
200
797
Combustible wall
283
515
750
750
50
50
585
Fire-retardant wall of
brick or concrete
432**
700
1000
233
50
200**
Fire-retardant wall of
brick or concrete
732
500
400
400
283
100
Combustible wall