GB
20
!
The minimum distance in front of the
stove opening to combustible parts
of the building or interior decoration
must be at least 1,1 m.
The dimension diagrams only show
the minimum permitted installation
distances for the stove. When con-
necting to a steel flue, also note the
safety distance requirements of the
flue. The safety distance between an
uninsulated flue and a combustible
part of the building should be at
least 450 mm.
Installation distances
A = height from floor to chimney
connection upwards
B = height from floor to c/c chimney
connection rear
C = height from floor to air inlet
D = height from floor to lower edge
of hatch
E = minimum height to sloped ceiling
from the centre of the chimney
A separate glass hearth
plate (accessory)
increases the connection
height to the chimney by
10 mm.
Permitted area for
combustible parts
of the building
* If the stove is placed on a hearth plate made of glass for example (accessory), the height from the floor is affected by a distance corresponding to the thickness of the hearth plate, for a free standing
glass hearth plate this is 10 mm.
** To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.
INSTALLATION AGAINST COMBUSTIBLE WALLS
INSTALLATION AGAINST FIREWALLS
C890T / C890TG Style
465
1275
2100
93
192
D 354
Combustible roof
365
183
A 1005*
113
B 916*
46
C 370
Ø150
Air inlet Ø67
308
540
620
75
75
Combustible wall
283
515
600
600
50
50
585
Fire-retardant wall of
brick or concrete
432**
233
50
200**
700
1000
Fire-retardant wall of
brick or concrete
582
350
350
350
283
100
Combustible wall
2100
E 630
100
Summary of Contents for Contura 890T Style
Page 1: ...890T Style 890TG Style contura eu...
Page 11: ...43 13 13 VANADI UM No 7 CHROME 2 1...
Page 12: ...44 x4 5 4 3...
Page 13: ...45 203082 203079 203084 203081 203080 203083 6 7...
Page 14: ...46 8...
Page 15: ...47 2 3 1...
Page 18: ...50 1 2 1 2 1 2 5 7 9 6 8...
Page 19: ...51 1 2 11 12 10...
Page 20: ...811388 IAV SE EX C890T Style 5 2022 06 22 NIBE AB Box 134 285 23 Markaryd Sweden contura eu...