Program settings
Program setting of AXC 50 can be performed via the start
guide or directly in the menu system.
Start guide
The start guide appears upon first start-up after heat
pump installation, but is also found in menu 5.7.
Menu system
If you do not make all settings via the start guide or need
to change any of the settings, this can be done in the
menu system.
Menu 5.2.4 - accessories
Activating/deactivating of accessories.
Select: "passive cooling 4-pipe".
Menu 1.1 - temperature
Setting indoor temperature (room temperature sensor is
required).
Menu 1.9.5 - cooling settings
Here you can perform the following settings:
႑
Lowest flow line temperature when cooling.
႑
Desired flow temperature at an outdoor air temperature
of +20 and +40 °C.
႑
Time between cooling and heating or vice versa.
႑
Selection of room sensor can control cooling.
႑
How much the room temperature may decrease or in-
crease compared to the desired temperature before
switching to heating respectively cooling (requires room
sensor).
႑
Misc. shunt settings.
Menu 4.9.2 - auto mode setting
When heat pump operating mode is set to "auto“ it se-
lects when start and stop of additional heat, heat produc-
tion and cooling is permitted, dependent on the average
outdoor temperature.
Select the average outdoor temperatures in this menu.
You can also set the time over which (filtering time) the
average temperature is calculated. If you select 0, the
present outdoor temperature is used.
Menu 5.6 - forced control
Forced control of the different components in the heat
pump as well as in the different accessories that may be
connected.
EQ1-AA5-K1: Activating the circulation pump (GP13).
EQ1-AA5-K2: Signal (close) to mixing valve (QN18).
EQ1-AA5-K3: Signal (open) to mixing valve (QN18).
EQ1-AA5-K4: No function.
Caution
Also see the Operating manual for F1345.
31
Chapter 8 |
Passive cooling (4-pipe)
AXC 50
Summary of Contents for AXC 50
Page 1: ...Installer manual LEK AXC 50 Accessories IHB GB 1222 1 231158...
Page 2: ......
Page 10: ...Electrical circuit diagram AXC 50 Chapter 3 Shunt controlled additional heat 8...
Page 15: ...Electrical circuit diagram 13 Chapter 4 Step controlled additional heat AXC 50...
Page 21: ...Electrical circuit diagram 19 Chapter 5 Extra climate system AXC 50...
Page 26: ...Electrical circuit diagram AXC 50 Chapter 6 Hot water comfort 24...
Page 29: ...Electrical circuit diagram 27 Chapter 7 Groundwater pump AXC 50...
Page 34: ...Electrical circuit diagram AXC 50 Chapter 8 Passive cooling 4 pipe 32...
Page 40: ...Electrical circuit diagram AXC 50 Chapter 9 Passive cooling 2 pipe 38...
Page 46: ...Electrical circuit diagram AXC 50 Chapter 10 Passive active cooling 2 pipe 44...
Page 47: ......
Page 48: ...NIBE AB Sweden Hannabadsv gen 5 Box 14 SE 285 21 Markaryd info nibe se www nibe eu 231158...