ELECTRICAL CIRCUIT DIAGRAM
Part Specification Sheet 051069-8
Page 2/2 Created:2020-01-09 09:30
JOV
2020-01-09
Production
SWI
2012-10-24
0.001
WIRING DIAGRAM ACS 310 ELSCHEMA ACS 310
051069
8
Pool heating
GENERAL
This function enables pool heating in your climate unit.
A reversing valve (CL11-QN19) is connected to control
the heating medium supply to a pool exchanger. The
reversing valve or, if required, the reversing valves (al-
though with the same control signal), is/are installed on
the heating medium circuit that normally goes to an
underfloor heating/radiator system.
AXC 30 S-series | GB
32
S