background image

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION

RTI-12309

Rear Transition Interface for Generic DIO/AO/AI with 8 IX Headers

Read this document before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring

instructions in addition to requirements of all applicable codes, laws, and standards. Visit 

ni.com/manuals

 for more information about your product, including

specifications, pinouts, and instructions for connecting, installing, and configuring your system.

Icons

Refer to the following descriptions if one of these icons is marked on your product or used in this guide.

Notice

 Take precautions to avoid data loss, loss of signal integrity, degradation of performance, or damage to the product.

Caution

 Take precautions to avoid injury. Consult the product documentation for cautionary statements when you see this icon printed on the

product. Cautionary statements are localized into French for compliance with Canadian requirements.

Safety Guidelines

Caution

 

Observe all instructions and cautions in the user documentation. Using the product in a manner not specified can damage the product and

compromise the built-in safety protection.

Attention

 

Suivez toutes les instructions et respectez toutes les mises en garde de la documentation d'utilisation. L'utilisation du produit de toute autre

façon que celle spécifiée risque de l'endommager et de compromettre la protection de sécurité intégrée.

Safety Current and Voltage Limits

Maximum working current and voltage

JR1

8 A per contact, 60 V DC

JR2 to JR9

0.75 A per contact, 32 V peak

Maximum working voltage

 refers to the signal voltage plus the common-mode voltage, and applies to both channel-to-channel and channel-to-earth.

Caution

 

Do not supply hazardous voltages (>30 V

RMS

 /42 V

peak

 /60 V

dc

) to the RTI-12309.

Attention

 

Ne pas alimenter le RTI-12309 avec des tensions dangereuses (> 30 V

eff

 / 42 V

pic

 / 60 V

cc

 ).

Caution

 

Do not connect the RTI-12309 to signals or use for measurements within Measurement Categories II, III, or IV.

Attention

 

Ne connectez pas le RTI-12309 à des signaux et ne l'utilisez pas pour effectuer des mesures dans les catégories de mesure II, III ou IV.

Caution

 

Source must be limited to not exceed rated maximum current and voltage.

Attention

 

La source doit être limitée de manière à ne pas dépasser le courant nominal maximal, ni la tension nominale maximale.

This product is rated for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS.

MAINS is a hazardous live electrical supply system to which equipment is designed to be connected to for the purpose of powering equipment. This product is

rated for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-

energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics.

Safety Compliance Standards

This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:
• IEC 61010-1, EN 61010-1
• UL 61010-1, CSA C22.2 No. 61010-1

Note

 

For safety certifications, refer to the product label or the 

Product Certifications and Declarations

 section.

Summary of Contents for RTI-12309

Page 1: ...8 A per contact 60 V DC JR2 to JR9 0 75 A per contact 32 V peak Maximum working voltage refers to the signal voltage plus the common mode voltage and applies to both channel to channel and channel to earth Caution Do not supply hazardous voltages 30 VRMS 42 Vpeak 60 Vdc to the RTI 12309 Attention Ne pas alimenter le RTI 12309 avec des tensions dangereuses 30 Veff 42 Vpic 60 Vcc Caution Do not conn...

Page 2: ...t damage industry standard ESD prevention measures must be employed during installation maintenance and operation Notice Operate this product only with shielded cables and accessories Notice The length of all I O cables must be no longer than 3 m 10 ft EMC Standards This product meets the requirements of the following EMC standards for electrical equipment for measurement control and laboratory us...

Page 3: ...t control laws and sanctions regulations This product may also be subject to additional license requirements of other countries regulations Additionally this product may also require export licensing before being returned to NI The issuance of a Return Material Authorization RMA by NI does not constitute export authorization The user must comply with all applicable export laws prior to exporting o...

Page 4: ...com trademarks for information on NI trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering NI products technology refer to the appropriate location Help Patents in your software the patents txt file on your media or the National Instruments Patent Notice at ni com patents You can find information about end user ...