Table 10. LED Indicators
LED
Indications
ACCESS Indicates the basic hardware status of the module.
•
OFF
—The driver software has not yet loaded, or the module exceeded
approved operating temperature and thermal shutdown occurred or has
detected a problem with a power rail.
•
AMBER
—The module is being accessed.
Accessed
means that the device
setup registers are being written to in order to control the device.
•
GREEN
—The module is ready to be programmed by software.
ACTIVE •
OFF
—The module is idle.
•
RED
—The module detected an error state.
PXIe-5830 Getting Started Guide
|