background image

MXI™, National Instruments™, NI™, and ni.com™ are trademarks of National Instruments Corporation. 
Product and company names mentioned herein are trademarks or trade names of their respective 
companies. For patents covering National Instruments products, refer to the appropriate location: 

Help»Patents

 in your software, the 

patents.txt

 file on your CD, or 

ni.com/patents

.

© 2003 National Instruments Corp. All rights reserved.

323753A-01

Dec03

*323753A-01*

Technical Support Resources

National Instruments corporate headquarters is located at 
11500 North Mopac Expressway, Austin, Texas, 78759-3504. 
National Instruments also has offices located around the world to help 
address your support needs. You can access our branch office Web sites 
from the Worldwide Offices section of 

ni.com

. Branch office Web sites 

provide up-to-date contact information, support phone numbers, email 
addresses, and current events. 

If you have searched the technical support resources on our Web site 
and still cannot find the answers you need, contact your local office or 
National Instruments corporate. For telephone support in the United States, 
dial 512 795 8248. For telephone support outside the United States, contact 
your local branch office: 

Australia 1800 300 800, Austria 43 0 662 45 79 90 0, Belgium 32 0 2 757 00 20, 
Brazil 55 11 3262 3599, Canada (Calgary) 403 274 9391, 
Canada (Ottawa) 613 233 5949, Canada (Québec) 450 510 3055, 
Canada (Toronto) 905 785 0085, Canada (Vancouver) 514 685 7530, 
China 86 21 6555 7838, Czech Republic 420 224 235 774, 
Denmark 45 45 76 26 00, Finland 385 0 9 725 725 11, France 33 0 1 48 14 24 24, 
Germany 49 0 89 741 31 30, Greece 30 2 10 42 96 427, India 91 80 51190000, 
Israel 972 0 3 6393737, Italy 39 02 413091, Japan 81 3 5472 2970, 
Korea 82 02 3451 3400, Malaysia 603 9131 0918, Mexico 001 800 010 0793, 
Netherlands 31 0 348 433 466, New Zealand 0800 553 322, 
Norway 47 0 66 90 76 60, Poland 48 22 3390150, Portugal 351 210 311 210, 
Russia 7 095 783 68 51, Singapore 65 6226 5886, Slovenia 386 3 425 4200, 
South Africa 27 0 11 805 8197, Spain 34 91 640 0085, Sweden 46 0 8 587 895 00, 
Switzerland 41 56 200 51 51, Taiwan 886 2 2528 7227, Thailand 662 992 7519, 
United Kingdom 44 0 1635 523545

Summary of Contents for PXI-8252

Page 1: ...items PXI 8252 card Number 1 Phillips screwdriver Installation The PXI 8252 card is easy to install and use It is an OHCI compliant 1394 device meaning the drivers are already provided in Windows 98 Second Edition and later Windows operating systems No configuration is required Once installed your PXI 8252 card is ready to use Hardware Installation Complete the following steps to install your PXI ...

Page 2: ...MXI 3 power on the PXI chassis first then power on the remote PC If you do not power on the chassis and remote system in the correct order the remote system will not recognize the PXI bus Windows 2000 XP Windows 2000 XP automatically detects the new card and installs the drivers You may be prompted for the original Windows 2000 XP CD Windows 98 Windows automatically detects the new hardware and di...

Page 3: ...r Windows Tip If Windows displays a dialog box indicating it cannot locate a file on the Windows 98 CD try inserting the Windows 98 installation CD telling Windows to copy files from either the top directory or the win98 directory of the CD ROM drive typically d or d win98 ...

Page 4: ...ng Started with NI PXI 8252 for Windows 4 ni com Windows Me Windows Me automatically detects the new hardware and displays an Add New Hardware Wizard window Choose the Recommended options when given a choice ...

Page 5: ...by 3 9 in 3U Connector 1394 Female 6 pin 3 PXI 32 bit Universal Signaling Signaling PXI Vio 3 3 V 5 V Universal 33 MHz 1394 IEEE 1394a 1995 S100 S200 S400 transfer rates OHCI v1 0 software interface Actual 1394 transfer rates are system dependent Power Consumption Typical 140 mA at 3 3 V Theoretical maximum 315 mA at 3 3 V 1 8 A at 5 0V 400 mA at 12 V Bus Power 1394 12 V 10 12 W total can be divid...

Page 6: ...standards of safety for electrical equipment for measurement control and laboratory use IEC 61010 1 EN 61010 1 UL 3111 1 UL 61010B 1 CAN CSA C22 2 No 1010 1 Note For UL and other safety certifications refer to the product label or visit ni com hardref nsf search by model number or product line and click the appropriate link in the Certification column Note The protection provided by this equipment...

Page 7: ...h shielded cabling CE Compliance This product meets the essential requirements of applicable European Directives as amended for CE marking as follows Low Voltage Directive safety 73 23 EEC Electromagnetic Compatibility Directive EMC 89 336 EEC Note Refer to the Declaration of Conformity DoC for this product for any additional regulatory compliance information To obtain the DoC for this product vis...

Page 8: ...nd the answers you need contact your local office or National Instruments corporate For telephone support in the United States dial 512 795 8248 For telephone support outside the United States contact your local branch office Australia 1800 300 800 Austria 43 0 662 45 79 90 0 Belgium 32 0 2 757 00 20 Brazil 55 11 3262 3599 Canada Calgary 403 274 9391 Canada Ottawa 613 233 5949 Canada Québec 450 51...

Reviews: