NI PCI-1426 Getting Started Download Page 3

©

 National Instruments Corporation

3

Getting Started with the NI PCI-1426

Measurement Category

1

: Measurement circuits are subjected to working voltages

2

 and transient 

stresses (overvoltage) from the circuit to which they are connected during measurement or test. 
Measurement Category establishes standardized impulse withstand voltage levels that commonly occur 
in electrical distribution systems. The following is a description of Measurement (Installation

3

Categories:

Measurement Category I is for measurements performed on circuits 

not

 directly connected to the 

electrical distribution system referred to as MAINS

4

 voltage. This category is for measurements of 

voltages from specially protected secondary circuits. Such voltage measurements include signal 
levels, special equipment, limited-energy parts of equipment, circuits powered by regulated 
low-voltage sources, and electronics.

Measurement Category II is for measurements performed on circuits directly connected to the 
electrical distribution system. This category refers to local-level electrical distribution, such as
that provided by a standard wall outlet (e.g., 115 V for U.S. or 230 V for Europe). Examples of 
Measurement Category II are measurements performed on household appliances, portable tools, 
and similar products.

Measurement Category III is for measurements performed in the building installation at the 
distribution level. This category refers to measurements on hard-wired equipment such as 
equipment in fixed installations, distribution boards, and circuit breakers. Other examples are 
wiring, including cables, bus-bars, junction boxes, switches, socket-outlets in the fixed installation, 
and stationary motors with permanent connections to fixed installations.

Unpacking

The NI 1426 ships in an antistatic package to prevent electrostatic discharge from damaging device 
components. To avoid such damage in handling your device, take the following precautions:

1.

Ground yourself using a grounding strap or by touching a grounded object, such as the computer 
chassis.

2.

Touch the antistatic package to a metal part of the computer chassis before removing the device 
from the package.

Caution

Never

 touch the exposed pins of connectors.

3.

Remove the device from the package and inspect it for loose components or any other signs of 
damage. Notify National Instruments if the device appears damaged in any way. Do 

not

 install

a damaged device in the computer.

Store the NI 1426 in the antistatic package when not in use.

1   

Measurement Categories as defined in electrical safety standard IEC 61010-1.

2   

Working voltage is the highest rms value of an AC or DC voltage that can occur across any particular insulation.

3   

Measurement Category is also referred to as Installation Category.

4   

MAINS is defined as the (hazardous live) electrical supply system to which equipment is designed to be connected for
the purpose of powering the equipment. Suitably rated measuring circuits may be connected to the MAINS for measuring 
purposes.

Summary of Contents for PCI-1426

Page 1: ...are for developing applications NI Vision Builder for Automated Inspection NI Vision Development Module LabVIEW LabWindows CVI Microsoft Visual Basic Optional Equipment National Instruments offers a variety of products for use with the NI 1426 including the following RTSI bus cables for connecting the NI 1426 to other Vision Motion Control or data acquisition devices 15 pin cable assembly kits for...

Page 2: ... introducing additional hazards do not install unauthorized parts or modify the device Use the device only with the chassis modules accessories and cables specified in the installation instructions All covers and filler panels must be installed while operating the device Do not operate the device in an explosive atmosphere or where flammable gases or fumes may be present Operate the device only at...

Page 3: ...This category refers to measurements on hard wired equipment such as equipment in fixed installations distribution boards and circuit breakers Other examples are wiring including cables bus bars junction boxes switches socket outlets in the fixed installation and stationary motors with permanent connections to fixed installations Unpacking The NI 1426 ships in an antistatic package to prevent elec...

Page 4: ...in Camera Link cable to the Base configuration Camera Link compatible camera Refer to your camera manufacturer documentation for specific instructions about how to connect the cable to your camera 10 Connect the Camera Link cable to the Camera Link connector on the NI 1426 front panel 11 Plug in and power on the computer The NI 1426 is now installed and the camera is connected Configuring the NI 1...

Page 5: ...ch of the configuration tree 3 Expand the NI IMAQ Devices branch 4 Expand the NI PCI 1426 branch 5 Right click Channel 0 and select Camera 6 Select your camera from the menu If your camera is not in the menu verify that the appropriate camera file is installed in the NI IMAQ Data directory Note If you lose communication with the camera during an acquisition for any reason such as unplugging a cabl...

Page 6: ...ial input threshold 0 2 V maximum RS 422 compatible Maximum quadrature count rate 5 MHz Note Camera Link cameras must transmit at a minimum of 20 MHz 1 Clocks Pixel clock frequency range 20 MHz to 50 MHz2 PCI Interface Theoretical max PCI bandwidth 133 MB s Memory Onboard memory 16 MB or 32 MB SDRAM depending on memory option purchased Serial Requirements Baud rates supported 300 600 1200 1800 200...

Page 7: ... the following standards of EMC for electrical equipment for measurement control and laboratory use EN 61326 EMC requirements Minimum Immunity EN 55011 Emissions Group 1 Class A CE C Tick ICES and FCC Part 15 Emissions Class A Note For EMC compliance operate this device to product documentation CE Compliance This product meets the essential requirements of applicable European Directives as amended...

Page 8: ... calibration you can obtain the calibration certificate for your product at ni com calibration National Instruments corporate headquarters is located at 11500 North Mopac Expressway Austin Texas 78759 3504 National Instruments also has offices located around the world to help address your support needs For telephone support in the United States create your service request at ni com support and fol...

Reviews: