background image

Table 3. Autonomous Mode Capabilities

Capability

Description

 

 

Use the Open/Close FPGA
Reference VI functions to run
an FPGA VI and then
disconnect the USB cable.

Call the Close FPGA VI Reference Function without
aborting or resetting the FPGA VI before you disconnect
the USB cable.

1

After you disconnect the USB cable, any VI running on the
NI USB-7846R continues to run and collect data, which
can later be retrieved by reconnecting the USB cable and
re-opening the original FPGA reference.

Use Interactive Front Panel
Communication to run an
FPGA VI and then
disconnecting the USB cable.

The front panel indicators stop updating.
After you disconnect the USB cable, any VI running on the
NI USB-7846R continues to run. Restore the Interactive
Front Panel Communication by reconnecting the USB
cable.

Download the bitfile to flash
memory and set it to run when
loaded to FPGA.

Download the bitfile to flash memory and set it to run when
loaded to FPGA. The bitfile automatically starts running
whenever power is applied to the NI USB-7846R. To
collect data, you must reconnect the NI USB-7846R to a
host computer before powering off the device.
Refer to the 

LabVIEW FPGA Module Help

 for more

information about downloading an FPGA VI to the flash
memory.

Worldwide Support and Services

The National Instruments website is your complete resource for technical support. At 

ni.com/

support

, you have access to everything from troubleshooting and application development

self-help resources to email and phone assistance from NI Application Engineers.

Visit 

ni.com/services

 for NI Factory Installation Services, repairs, extended warranty, and

other services.

Visit 

ni.com/register

 to register your National Instruments product. Product registration

facilitates technical support and ensures that you receive important information updates from
NI.

National Instruments corporate headquarters is located at 11500 North Mopac Expressway,
Austin, Texas, 78759-3504. National Instruments also has offices located around the world.
For telephone support in the United States, create your service request at 

ni.com/support

 or

dial 1 866 ASK MYNI (275 6964). For telephone support outside the United States, visit the

1

The Host VI errors out if you do not call the Close FPGA VI Reference Function without aborting
or resetting the FPGA VI.

12

  | 

ni.com

  | 

NI USB-7846R User Manual

Summary of Contents for 7846R

Page 1: ...product specifications These requirements and limits are designed to provide reasonable protection against harmful interference when the product is operated in its intended operational electromagneti...

Page 2: ...vervoltage Protection Overvoltage Protection FPGA Temperature 40 MHz OSC AO x8 USB NI ASIC Kintex 7 FPGA NI USB 7846R Flash Memory DIO 5 V Reference DAC AO ADC AI CONNECTOR 0 DIO CONNECTOR 1 MIO Data...

Page 3: ...DIO9 DIO11 DIO13 DIO15 AO7 AO6 AO5 AO4 AO3 AO2 AO1 AO0 AISENSE AI7 AIGND6 AI6 AI5 AIGND4 AI4 AI3 AIGND2 AI2 AI1 AIGND0 AI0 5V DGND DGND DGND DGND DGND DGND DGND DGND DIO8 DIO10 DIO12 DIO14 AOGND7 AOGN...

Page 4: ...ed or differential voltage signals Use the AISENSE pin to connect non referenced single ended signals Connecting Single Ended Voltage Signals To connect referenced single ended voltage signals to the...

Page 5: ...ial signals to the NI USB 7846R you must also connect the signal reference to AI GND Figure 5 Connecting Grounded Differential Signals to the NI USB 7846R PGIA ADC AI NI USB 7846R Connection Accessory...

Page 6: ...ect a load Figure 7 Connecting a Load NI USB 7846R Connection Accessory AOGND LOAD AO DAC Digital I O The NI USB 7846R provides connections for 48 digital input output DIO channels Connector 0 contain...

Page 7: ...t as input low with pull down resistors To set another power on state you can configure the NI USB 7846R to load a VI when the system powers on The VI can then set the DIO lines to any power on state...

Page 8: ...istance To reduce the magnetic coupling between lines separate them by a reasonable distance if they run in parallel or run the lines at right angles to each other Do not run signal lines through cond...

Page 9: ...s Tighten the screws to a torque of 0 4 N m 3 6 lb in 2 Clip the bracket onto the DIN rail as shown Figure 10 DIN Rail Clip Parts Locator Diagram 1 2 3 1 DIN Rail Clip 2 DIN Rail Spring 3 DIN Rail 3 P...

Page 10: ...riptions Symbol LED Description POWER Solid blue when the power is on USB READY Solid blue when the USB is ready ERROR Solid red for error cases 1 USER USER1 Blue user defined 2 USER USER2 Blue user d...

Page 11: ...ents is not liable for damage resulting from such a connection The power rating is 4 75 to 5 1 VDC at 0 5 A Autonomous Mode You can run the NI USB 7846R without a USB connection to a host computer usi...

Page 12: ...the NI USB 7846R to a host computer before powering off the device Refer to the LabVIEW FPGA Module Help for more information about downloading an FPGA VI to the flash memory Worldwide Support and Ser...

Page 13: ...s section of ni com niglobal to access the branch office websites which provide up to date contact information support phone numbers email addresses and current events NI USB 7846R User Manual Nationa...

Page 14: ...p Patents in your software the patents txt file on your media or the National Instruments Patent Notice at ni com patents You can find information about end user license agreements EULAs and third par...

Reviews: