High-accuracy Dual-channel Programmable DC Power Supply
41
Figure 35 Multiple Devices Connection Diagram
8.3 Connection to Computer
There are two LAN ports and one RS232 interface for remote communication.
The below steps is for remote control via LAN port:
1. Enter the N39200 Application Software on PC.
2. Find
Hardware Config
.
3. Select LAN for
Communication Mode
.
4. Set
IP
address. The IP should be consistent with IP of N39200.
5. Press
Detect
to connect with N39200.
After N39200 receives the correct communication instruction, it will start remote
control. Under remote control mode, local operation is disabled and N39200 can only
be controlled by programming instructions. Please press
L o c k
to return to local
operation.
Remote control and operation can be realized via the application software on PC. The
software installation program can be obtained from the USB flash drive.