background image

TEMPERATURE/ HUMIDITY WINDOW

ICON

STATUS

Searching for the signals from the 

remote sensor

Corresponding remote sensor signal

received successfully

No signals received for over 1 hour

SEARCH FOR REMOTE SENSORS 

• The main unit can be manually activated to search for 

the signals from remote sensors by pressing and holding 

DOWN (▼) button.

OPERATION

• To select the indoor/ outdoor temperature and humidity 

mode, press

 UP

 (▲) or

 DOWN

 (▼) until the 

IN

 icon   

flashes with a beep sound alert.

VIEWING REMOTE (CHANNEL) TEMPERATURE 

AND HUMIDITY

Static Display:

• Press the 

CHANNEL

 button to select measurements 

from different remote sensors, each is 

MODE

 to a unique 

channel 1, 2 or 3.

Channel Auto-Scan Display:

• To enable an automatic scan of all channels, press 

and hold 

CHANNEL

, until the   icon is displayed. The 

measurements from each remote channel will be 

alternately displayed for 5 seconds.

NOTE: the channel auto-scan feature can be active 

only if there are more than one remote sensors 

operating and are set to different channels. 
PROGRAMMING TEMPERATURE IN CELSIUS 

OR FAHRENHEIT

• Press and hold 

MODE

 button for 3 seconds to toggle the 

temperature unit in Celsius (ºC) or Fahrenheit (ºF).

17

Summary of Contents for 6319296

Page 1: ...6319296 Wireless Weather Forecaster With Indoor Outdoor Temperature and Humidity USER S MANUAL...

Page 2: ...onitoring and displaying of current temperature and humidity data from up to three remote locations In this package you will find One main unit receiver One remote sensor transmitter One User s Manual...

Page 3: ...n operating range of up to 100 feet 30 meters in an open area The remote temperature sensor can be placed indoors or outdoors depending on the area where the temperature is intended to be measured NOT...

Page 4: ...mote readings will appear on the main unit s display position the remote sensor and the main unit within the effective transmission range of up to 100 feet 30 meters The main unit must be placed indoo...

Page 5: ...d using built in hanger A LED INDICATOR Flashes once about every 45 seconds with each transmission to the main unit Flashes twice when battery power is low B BATTERY COMPARTMENT Requires two AA size b...

Page 6: ...ocated in the battery compartment Channel 1 is typically selected if only one remote sensor is being used Install 2 AA size alkaline batteries not included matching the polarities shown in the battery...

Page 7: ...gs Avoid placing the remote sensor near sources of heat such as chimneys and heating elements Avoid areas that collect heat from the sun and radiate heat such as metal brick or concrete structures pav...

Page 8: ...y in 7 languages English German French Italian Spanish Dutch and Swedish Dual crescendo alarms with snooze Programmable ice warning alarm WEATHER Weather forecast for the next 12 to 24 hour in seven l...

Page 9: ...MAIN UNIT 9 J A B C D E F I H G K L...

Page 10: ...or lowest temperature alarm s value Hold for 2 seconds set the highest or lowest temperature alarm s value When alarm is on press once to stop the alarm temporarily F CHANNEL button Press to display...

Page 11: ...o activate deactivate radio controlled time signal search manually In time with weekday display mode press and hold for 2 seconds to switch time zone from Pacific Mountain Central to Eastern I MEM HIS...

Page 12: ...ith interference from wireless devices e g cordless phones radio headsets baby monitoring devices and other electronics OPERATION Once the main unit is powered the display will show all available LCD...

Page 13: ...for the past 24 hours Pressure can be measured in inHg hPa mBar or mmHg and altitude is determined in either meters or feet IMPORTANT There are three viewing options available barometric pressure SEA...

Page 14: ...begins to flash Press MODE button to toggle through selections until SEA LEVEL or LOCAL barometric pressure is displayed Press and hold MEM HISTORY button to enter the pressure unit selection mode Pr...

Page 15: ...HISTORY until the pressure unit flashes Change local or sea level pressure units by pressing the UP or DOWN buttons to select the pressure units Choose from inHg hPa mBar or mmHg Press MEM HISTORY to...

Page 16: ...main unit supports up to 3 remote sensors corresponding to a separate channel of the temperature and relative humidity display The temperature can be displayed in Celsius C or Fahrenheit F The main un...

Page 17: ...REMOTE CHANNEL TEMPERATURE AND HUMIDITY Static Display Press the CHANNEL button to select measurements from different remote sensors each is MODE to a unique channel 1 2 or 3 Channel Auto Scan Display...

Page 18: ...Once the above alerts are displayed press the UP or DOWN to enable or disable the corresponding alert VIEWING MAX MIN READINGS Press the MEM HISTORY button recalling Current temperature and humidity...

Page 19: ...its an exact time signal continuously throughout most of the continental United States at 60 KHz frequency The main unit can receive this WWVB signal through the internal antenna from up to 2 000 mile...

Page 20: ...the window for better reception Once the atomic time signal is received the date and time will be set automatically and the icon will appear The atomic clock receiver is programmed to search for the a...

Page 21: ...map located to the right of the time display and above the day of the week Release the UP button The Time Zone is now set TIME AND CALENDAR Press and hold MODE button until the day of week language a...

Page 22: ...el One 1 reaches 0 C 32 F and below NOTE Ice Warning Alarm can be set only if one or both Weekday or Single alarm are programmed SETTING THE WEEKDAY W AND SINGLE DAY S ALARMS Press ALARM button once t...

Page 23: ...r 30 will flash meaning that if selected the alarm will sound 30 minutes prior to the Weekday or Single alarm Select the desired Ice Warning Alarm interval in 15 minutes increments between 15 and 90 m...

Page 24: ...ry service if handled carefully Here are a few precautions Do not immerse the units in water Do not clean the units with abrasive or corrosive materials They may scratch the plastic parts and corrode...

Page 25: ...it there overnight REMOTE SENSOR Cannot locate remote sensor Check batteries Check location Press and hold DOWN button on the main unit to search for the signal from the remote sensor Cannot change th...

Page 26: ...rainy heavy rain snowy and heavy snow Maximum number of remote sensors 3 one included Readings update interval every 45 seconds Low battery indicator Clock Precise atomic time 4 US Time Zones 12 24 h...

Page 27: ...e 30 to 80 Resolution 1 Accuracy 7 Sampling Interval 10 seconds Transmitting Interval around 47 seconds RF Transmission Frequency 433 MHz RF Range Maximum 30 meters 100 feet Temperature transmission c...

Page 28: ...termined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 reorient or relocate the receiving antenna 2 increase...

Page 29: ...applicable to a product purchased through The Source company owned stores and dealers and to a product that is presented for repair in a country where The Source offers the product for sale While thi...

Reviews: