PW5K1EN Ethernet Daughter
Installation Guide
12
TD1120 rev1101
After the networking portion of the setup has been completed, the
serial port setup will appear. The values here will apply to the serial
port on the MSS Device. For optimum performance it is recom-
mended that the "Port Speed" be set at 38400, "Access" be set as
"Remote", and that "Flow Control" be changed to "None". Leave
the other entries at their defaulted value. Click on the "Next" button.
After completion of the serial port setup, the configuration is
complete. The next screen will allow the user to summarize and
edit the configuration, save the configuration to disk, or download
the configuration to the MSS Device.
• Download the configuration, and Reboot as per the prompt's
request. This completes the EZWebCon setup.