![Nextek Vari-Fan Installation Instructions Manual Download Page 4](http://html1.mh-extra.com/html/nextek/vari-fan/vari-fan_installation-instructions-manual_1684239004.webp)
Installation Instructions For Vari-Cylone Ceiling Fans
|
|
Installation Instructions For Vari-Cyclone Ceiling Fans
For more information:
Nextek Power Systems
Tel: 313.887.1321
www.nextekpower.com
461 Burroughs Street
Toll free: 1 (877) 24-VOLTS
Detroit, Michigan 48202
Fax: 313.887.9433
For more information:
Nextek Power Systems
Tel: 313.887.1321
www.nextekpower.com
461 Burroughs Street
Toll free: 1 (877) 24-VOLTS
Detroit, Michigan 48202
Fax: 313.887.9433
2
11
WARRANTY:
All fan bodies and fan motors are
warranted against defect for one (1) year
from time of sale. Please keep any dated
invoices or sales receipts for proof of
purchase.
DISCLAIMER:
All DC powered ceiling fan motors are
rated for one (1) amp maximum input.
All warranties on the motor and body
part are voided if the power input to the
motor exceeds one (1) amp.
When operating an DC powered ceiling
fan directly from a Photo Voltaic (PV)
panel, without a battery in the circuit, be
sure the output of the panel does not
exceed 20 watts at 12 or 24 Vdc.
THIS WILL VOID YOUR WARRANTY.
I
IMPORTANT INFORMATION :
1. It is recommended that all Nextek
Fanworks DC ceiling fans be used in
conjunction with the Nextek 12/24V
Speed Controller.
2. If operating in a 12V environment, the
12/24V speed control is required.
3. The Nextek DC ceiling fans can be
operated above 24VDC, but not to
exceed 48VDC. A 48VDC Speed
Controller can be special ordered. The
12/24V speed control is designed to work
only between 12V and 24V.
4. A Nextek 12.6 watt solar panel is
available and perfectly matched for
this DC powered ceiling fan and speed
control.
5. For new installations: This is a low-
voltage 12/24V DC-powered device.
Appropriate sizing of a solar panel,
CAUTION:
1. Read entire instructions carefully before
beginning installation.
2. To avoid possible electrical shock, be certain
electricity is shut off at main panel before
wiring.
3. All wiring must be in accordance with
national and local electrical codes. If you
are unfamiliar with wiring, you should use a
qualified electrician.
WARNING:
1. To reduce the risk of fire or electrical shock
use Nextek 12/24V speed controls only.
2. To reduce the risk of personal injury, do not
bend the blade brackets when installing the
brackets or cleaning the fan. Do not insert
foreign objects in between rotating fan
blades.
3. To reduce the risk of personal injury, install
the fan only to the building structure
according to these instructions, and use only
the hardware supplied.
!
MY FAN MAKES A RUBBING SOUND WHEN RUNNING:
Turn your fan off, when the blades have stopped turning, spin the fan with your hand, if you hear the
rubbing sound, it is most likely that the fan’s hub is rubbing against the motor housing.
Loosen the hub’s set screw; remove the decorative knob covering the fan’s motor shaft. Using a flat
bladed screw driver, pry the safety push nut away from the hub (about 1/8 inch) Try spinning the fan
again, if the rubbing sound is gone, then re-tighten the set screw and replace the decorative knob.
MY FANS BLADES SEEM TO GO UP AND DOWN AS THE FAN SPINS:
Turn fan off, gently rotate hub by hand, look for the high and low movement of the blades. Grab the
hub at the high spot with one hand, with your other hand, grab the low spot, then “gently” push the
low side of the hub up while pulling down on the high side. Spin the hub again and see if the up/down
wobble is gone, if not, repeat the procedure until problem is fixed.
battery and battery charge controller are
essential for proper operation. Consult a
qualified installer of DC devices to insure
correct configuration.
6. For installation in existing DC power
environment: Great care must be taken
to ensure fan is wired properly in existing
DC power environment. Warranty may
be violated if attempting to operate in
anything other than 12/24V DC. Please
consult a qualified technician.
7. Failure to wire correctly or install in non-
recommended power environment may
violate your warranty.
Installation Instructions For Vari-Cylone Ceiling Fans
|
|
Installation Instructions For Vari-Cyclone Ceiling Fans
For more information:
Nextek Power Systems
Tel: 313.887.1321
www.nextekpower.com
461 Burroughs Street
Toll free: 1 (877) 24-VOLTS
Detroit, Michigan 48202
Fax: 313.887.9433
For more information:
Nextek Power Systems
Tel: 313.887.1321
www.nextekpower.com
461 Burroughs Street
Toll free: 1 (877) 24-VOLTS
Detroit, Michigan 48202
Fax: 313.887.9433
2
11
WARRANTY:
All fan bodies and fan motors are
warranted against defect for one (1) year
from time of sale. Please keep any dated
invoices or sales receipts for proof of
purchase.
DISCLAIMER:
All DC powered ceiling fan motors are
rated for one (1) amp maximum input.
All warranties on the motor and body
part are voided if the power input to the
motor exceeds one (1) amp.
When operating an DC powered ceiling
fan directly from a Photo Voltaic (PV)
panel, without a battery in the circuit, be
sure the output of the panel does not
exceed 20 watts at 12 or 24 Vdc.
THIS WILL VOID YOUR WARRANTY.
I
IMPORTANT INFORMATION :
1. It is recommended that all Nextek
Fanworks DC ceiling fans be used in
conjunction with the Nextek 12/24V
Speed Controller.
2. If operating in a 12V environment, the
12/24V speed control is required.
3. The Nextek DC ceiling fans can be
operated above 24VDC, but not to
exceed 48VDC. A 48VDC Speed
Controller can be special ordered. The
12/24V speed control is designed to work
only between 12V and 24V.
4. A Nextek 12.6 watt solar panel is
available and perfectly matched for
this DC powered ceiling fan and speed
control.
5. For new installations: This is a low-
voltage 12/24V DC-powered device.
Appropriate sizing of a solar panel,
CAUTION:
1. Read entire instructions carefully before
beginning installation.
2. To avoid possible electrical shock, be certain
electricity is shut off at main panel before
wiring.
3. All wiring must be in accordance with
national and local electrical codes. If you
are unfamiliar with wiring, you should use a
qualified electrician.
WARNING:
1. To reduce the risk of fire or electrical shock
use Nextek 12/24V speed controls only.
2. To reduce the risk of personal injury, do not
bend the blade brackets when installing the
brackets or cleaning the fan. Do not insert
foreign objects in between rotating fan
blades.
3. To reduce the risk of personal injury, install
the fan only to the building structure
according to these instructions, and use only
the hardware supplied.
!
MY FAN MAKES A RUBBING SOUND WHEN RUNNING:
Turn your fan off, when the blades have stopped turning, spin the fan with your hand, if you hear the
rubbing sound, it is most likely that the fan’s hub is rubbing against the motor housing.
Loosen the hub’s set screw; remove the decorative knob covering the fan’s motor shaft. Using a flat
bladed screw driver, pry the safety push nut away from the hub (about 1/8 inch) Try spinning the fan
again, if the rubbing sound is gone, then re-tighten the set screw and replace the decorative knob.
MY FANS BLADES SEEM TO GO UP AND DOWN AS THE FAN SPINS:
Turn fan off, gently rotate hub by hand, look for the high and low movement of the blades. Grab the
hub at the high spot with one hand, with your other hand, grab the low spot, then “gently” push the
low side of the hub up while pulling down on the high side. Spin the hub again and see if the up/down
wobble is gone, if not, repeat the procedure until problem is fixed.
battery and battery charge controller are
essential for proper operation. Consult a
qualified installer of DC devices to insure
correct configuration.
6. For installation in existing DC power
environment: Great care must be taken
to ensure fan is wired properly in existing
DC power environment. Warranty may
be violated if attempting to operate in
anything other than 12/24V DC. Please
consult a qualified technician.
7. Failure to wire correctly or install in non-
recommended power environment may
violate your warranty.
For more information:
Nextek Power Systems
Tel: 313.887.1321
www.nextekpower.com
461 Burroughs Street
Toll free: 1 (877) 24-VOLTS
Detroit, Michigan 48202
Fax: 313.887.9433
For more information:
Nextek Power Systems
Tel: 313.887.1321
www.nextekpower.com
461 Burroughs Street
Toll free: 1 (877) 24-VOLTS
Detroit, Michigan 48202
Fax: 313.887.9433
|
Installation Instructions For Vari-Fan Ceiling Fans
Installation Instructions For Vari-Fan Ceiling Fans
|
7. Lift completed motor and hub assembly
to mounting bracket on ceiling, and slip
one hole on side of mounting cone over
hook on bracket.
8. With motor and assembly hanging from
hook, connect fan wires to the house
wires using three (3) wire nuts included
with fan. Connect white wire of fan to
the negative power house wire and the
black wire of the fan to the positive
power house wire. The green wire
should be connected to the ground wire
on the mounting bracket. Fan should
operate in a counter-clockwise direction
for downward draw (Summer). For
upward draw (Winter), use the reverse
button on the Speed Controller.
9. After wires are connected, remove
fan from hook, and slip mounting cone
over mounting bracket. Align the open
holes of cone with the two screws, and
rotate until cone will stay in place. Then
replace the other two screws in cone
and tighten all four screws firmly.
8
5
Parts Information
01 1 x Mounting Bracket
02. 4 x 10/32 x 3/8 P.H. Phillips
03 1 x Mounting cone
04 4 x 10/32 x 3/8” P.H.Phillips
05 1 x Pivot Ball
06 1 x Retaining Pin
07 1 x Down Rod
08 1 x Pin & Clip
09 1 x 10/32 x 3/8 P.H. Phillips
10 4 x 8/32 x 1/2 F.H. Phillips
11 1 x Receptacle
12 1 x Motor Housing
13 1 x Fan Motor
14 1 x Hub
15 1 x 1/4 /20 x 5/16 Set Screw
16 10 x 10/32 x 3/8 P.H. Phillips
17 1 x Retaining Clip
18 1 x Retaining Knob
19 15 x 10/32 x 1/2 P.H. Phillips
20 15 x Washers
21 5 x Fan Blades
22 5 x Blade Arms
10. Turn on power, and check that motor
shaft is turning in a counter clockwise
direction.
Turn power off.
11. Assemble blade arm (#22) and fan
blades (#21) using the 15 screws and
washers (#20) that are in bag with blade
arms.
12. Once the blades and arms are
assembled, attach the assemblies to the
hub using the bag of 10 screws (#16).
The inside hole pattern on the hub is for
four (4) blades.
The outside hole pattern on the hub is
for five (5) blades.
13. Turn on your fan
For more information:
Nextek Power Systems
Tel: 313.887.1321
www.nextekpower.com
461 Burroughs Street
Toll free: 1 (877) 24-VOLTS
Detroit, Michigan 48202
Fax: 313.887.9433
For more information:
Nextek Power Systems
Tel: 313.887.1321
www.nextekpower.com
461 Burroughs Street
Toll free: 1 (877) 24-VOLTS
Detroit, Michigan 48202
Fax: 313.887.9433
|
Installation Instructions For Vari-Fan Ceiling Fans
Installation Instructions For Vari-Fan Ceiling Fans
|
7. Lift completed motor and hub assembly
to mounting bracket on ceiling, and slip
one hole on side of mounting cone over
hook on bracket.
8. With motor and assembly hanging from
hook, connect fan wires to the house
wires using three (3) wire nuts included
with fan. Connect white wire of fan to
the negative power house wire and the
black wire of the fan to the positive
power house wire. The green wire
should be connected to the ground wire
on the mounting bracket. Fan should
operate in a counter-clockwise direction
for downward draw (Summer). For
upward draw (Winter), use the reverse
button on the Speed Controller.
9. After wires are connected, remove
fan from hook, and slip mounting cone
over mounting bracket. Align the open
holes of cone with the two screws, and
rotate until cone will stay in place. Then
replace the other two screws in cone
and tighten all four screws firmly.
8
5
Parts Information
01 1 x Mounting Bracket
02. 4 x 10/32 x 3/8 P.H. Phillips
03 1 x Mounting cone
04 4 x 10/32 x 3/8” P.H.Phillips
05 1 x Pivot Ball
06 1 x Retaining Pin
07 1 x Down Rod
08 1 x Pin & Clip
09 1 x 10/32 x 3/8 P.H. Phillips
10 4 x 8/32 x 1/2 F.H. Phillips
11 1 x Receptacle
12 1 x Motor Housing
13 1 x Fan Motor
14 1 x Hub
15 1 x 1/4 /20 x 5/16 Set Screw
16 10 x 10/32 x 3/8 P.H. Phillips
17 1 x Retaining Clip
18 1 x Retaining Knob
19 15 x 10/32 x 1/2 P.H. Phillips
20 15 x Washers
21 5 x Fan Blades
22 5 x Blade Arms
10. Turn on power, and check that motor
shaft is turning in a counter clockwise
direction.
Turn power off.
11. Assemble blade arm (#22) and fan
blades (#21) using the 15 screws and
washers (#20) that are in bag with blade
arms.
12. Once the blades and arms are
assembled, attach the assemblies to the
hub using the bag of 10 screws (#16).
The inside hole pattern on the hub is for
four (4) blades.
The outside hole pattern on the hub is
for five (5) blades.
13. Turn on your fan
For more information:
Nextek Power Systems
Tel: 313.887.1321
www.nextekpower.com
461 Burroughs Street
Toll free: 1 (877) 24-VOLTS
Detroit, Michigan 48202
Fax: 313.887.9433
For more information:
Nextek Power Systems
Tel: 313.887.1321
www.nextekpower.com
461 Burroughs Street
Toll free: 1 (877) 24-VOLTS
Detroit, Michigan 48202
Fax: 313.887.9433
|
Installation Instructions For Vari-Fan Ceiling Fans
Installation Instructions For Vari-Fan Ceiling Fans
|
12. Push retaining knob (#18) onto motor
shaft until it is firmly against the hub.
13. Lift completed motor and hub assembly
to mounting bracket on ceiling, and slip
one hole on side of mounting cone over
hook on bracket.
14. With motor and assembly hanging from
hook, connect fan wires to the house
wires using three (3) wire nuts included
with fan. Fan should only be operated in
a counter-clockwise direction. Connect
white wire of fan to the negative power
house wire and the black wire of the fan
to the positive power house wire. The
green wire should be connected to the
ground wire on the mounting bracket.
15. After wires are connected, remove
fan from hook, and slip mounting cone
over mounting bracket. Align the open
holes of cone with the two screws, and
rotate until cone will stay in place. Then
replace the other two screws in cone
and tighten all four screws firmly.
6
7
6. Remove retaining pin and retaining clip
(#08) from receptacle.
7. Slip down rod into receptacle, and align
holes of rod with hole in receptacle.
8. Re-insert pin through receptacle/down
rod assembly and attach clip.
9. Tighten screw on side of receptacle.
10. Align the hub (#14) with the motor
shaft (#13). Align the flat side of the
motor shaft to the Allen Screw hole.
Push hub onto shaft until 3/8” (1cm) of
the shaft protrudes from the hub.
Tighten set screw using Allan Wrench
included with fan.
IMPORTANT:
To prevent wobble, make sure the FLAT of the motor
shaft is aligned with the FLAT of the center of hub. The set screw
should be tightened against the center of the FLAT of the motor
shaft.
11. Push retaining clip (#17) onto motor
shaft unit until it is firmly against the
hub.
WARNING:
Failure to install the retain clip tightly against the hub
as described may cause separation of the hub during fan operation.
Serious injury may result. Consult a qualified installer if in any
doubt about installation procedures.
Step 4.2: Fan Assembly Down Rod Version
Follow the instructions below for
installation of down rod ceiling fan.
1. Remove mounting bracket (#1) from
mounting cone.(#3) Leave the screws in
the bracket that match up with the open
hole on each side of mounting cone.
2. Attach mounting bracket to junction
box or directly to ceiling using screws
taped to mounting bracket.
Lead wires through center hole in
bracket.
3. Remove the four screws (#04) holding
the mounting cone (#3) to top of fan.
Remove cone from top of fan.
4. Put down rod (#07) through mount
cone (pivot ball (#05)end of rod remains
in cone).
5. Feed wires from receptacle through
bottom of down rod (#07) and out
through the pivot ball end.
41228-01 12/95
- 2 -
©1995 HUNTER FAN CO.™
16. Turn on power, and check that motor
shaft is turning in a counter clockwise
direction.
Turn power off.
17. Assemble blade arm (#22) and fan
blades (#21) using the 15 screws and
washers (#20) that are in bag with blade
arms.
18. Once the blades and arms are
assembled, attach the assemblies to the
hub using the bag of 10 screws (#16).
The inside hole pattern on the hub is
for four (4) blades.
The outside hole pattern on the hub is
for five (5) blades.
19. Turn on your fan
For more information:
Nextek Power Systems
Tel: 313.887.1321
www.nextekpower.com
461 Burroughs Street
Toll free: 1 (877) 24-VOLTS
Detroit, Michigan 48202
Fax: 313.887.9433
For more information:
Nextek Power Systems
Tel: 313.887.1321
www.nextekpower.com
461 Burroughs Street
Toll free: 1 (877) 24-VOLTS
Detroit, Michigan 48202
Fax: 313.887.9433
|
Installation Instructions For Vari-Fan Ceiling Fans
Installation Instructions For Vari-Fan Ceiling Fans
|
12. Push retaining knob (#18) onto motor
shaft until it is firmly against the hub.
13. Lift completed motor and hub assembly
to mounting bracket on ceiling, and slip
one hole on side of mounting cone over
hook on bracket.
14. With motor and assembly hanging from
hook, connect fan wires to the house
wires using three (3) wire nuts included
with fan. Fan should only be operated in
a counter-clockwise direction. Connect
white wire of fan to the negative power
house wire and the black wire of the fan
to the positive power house wire. The
green wire should be connected to the
ground wire on the mounting bracket.
15. After wires are connected, remove
fan from hook, and slip mounting cone
over mounting bracket. Align the open
holes of cone with the two screws, and
rotate until cone will stay in place. Then
replace the other two screws in cone
and tighten all four screws firmly.
6
7
6. Remove retaining pin and retaining clip
(#08) from receptacle.
7. Slip down rod into receptacle, and align
holes of rod with hole in receptacle.
8. Re-insert pin through receptacle/down
rod assembly and attach clip.
9. Tighten screw on side of receptacle.
10. Align the hub (#14) with the motor
shaft (#13). Align the flat side of the
motor shaft to the Allen Screw hole.
Push hub onto shaft until 3/8” (1cm) of
the shaft protrudes from the hub.
Tighten set screw using Allan Wrench
included with fan.
IMPORTANT:
To prevent wobble, make sure the FLAT of the motor
shaft is aligned with the FLAT of the center of hub. The set screw
should be tightened against the center of the FLAT of the motor
shaft.
11. Push retaining clip (#17) onto motor
shaft unit until it is firmly against the
hub.
WARNING:
Failure to install the retain clip tightly against the hub
as described may cause separation of the hub during fan operation.
Serious injury may result. Consult a qualified installer if in any
doubt about installation procedures.
Step 4.2: Fan Assembly Down Rod Version
Follow the instructions below for
installation of down rod ceiling fan.
1. Remove mounting bracket (#1) from
mounting cone.(#3) Leave the screws in
the bracket that match up with the open
hole on each side of mounting cone.
2. Attach mounting bracket to junction
box or directly to ceiling using screws
taped to mounting bracket.
Lead wires through center hole in
bracket.
3. Remove the four screws (#04) holding
the mounting cone (#3) to top of fan.
Remove cone from top of fan.
4. Put down rod (#07) through mount
cone (pivot ball (#05)end of rod remains
in cone).
5. Feed wires from receptacle through
bottom of down rod (#07) and out
through the pivot ball end.
41228-01 12/95
- 2 -
©1995 HUNTER FAN CO.™
16. Turn on power, and check that motor
shaft is turning in a counter clockwise
direction.
Turn power off.
17. Assemble blade arm (#22) and fan
blades (#21) using the 15 screws and
washers (#20) that are in bag with blade
arms.
18. Once the blades and arms are
assembled, attach the assemblies to the
hub using the bag of 10 screws (#16).
The inside hole pattern on the hub is
for four (4) blades.
The outside hole pattern on the hub is
for five (5) blades.
19. Turn on your fan
For more information:
Nextek Power Systems
Tel: 313.887.1321
www.nextekpower.com
461 Burroughs Street
Toll free: 1 (877) 24-VOLTS
Detroit, Michigan 48202
Fax: 313.887.9433
For more information:
Nextek Power Systems
Tel: 313.887.1321
www.nextekpower.com
461 Burroughs Street
Toll free: 1 (877) 24-VOLTS
Detroit, Michigan 48202
Fax: 313.887.9433
|
Installation Instructions For Vari-Fan Ceiling Fans
Installation Instructions For Vari-Fan Ceiling Fans
|
12. Push retaining knob (#18) onto motor
shaft until it is firmly against the hub.
13. Lift completed motor and hub assembly
to mounting bracket on ceiling, and slip
one hole on side of mounting cone over
hook on bracket.
14. With motor and assembly hanging from
hook, connect fan wires to the house
wires using three (3) wire nuts included
with fan. Fan should only be operated in
a counter-clockwise direction. Connect
white wire of fan to the negative power
house wire and the black wire of the fan
to the positive power house wire. The
green wire should be connected to the
ground wire on the mounting bracket.
15. After wires are connected, remove
fan from hook, and slip mounting cone
over mounting bracket. Align the open
holes of cone with the two screws, and
rotate until cone will stay in place. Then
replace the other two screws in cone
and tighten all four screws firmly.
6
7
6. Remove retaining pin and retaining clip
(#08) from receptacle.
7. Slip down rod into receptacle, and align
holes of rod with hole in receptacle.
8. Re-insert pin through receptacle/down
rod assembly and attach clip.
9. Tighten screw on side of receptacle.
10. Align the hub (#14) with the motor
shaft (#13). Align the flat side of the
motor shaft to the Allen Screw hole.
Push hub onto shaft until 3/8” (1cm) of
the shaft protrudes from the hub.
Tighten set screw using Allan Wrench
included with fan.
IMPORTANT:
To prevent wobble, make sure the FLAT of the motor
shaft is aligned with the FLAT of the center of hub. The set screw
should be tightened against the center of the FLAT of the motor
shaft.
11. Push retaining clip (#17) onto motor
shaft unit until it is firmly against the
hub.
WARNING:
Failure to install the retain clip tightly against the hub
as described may cause separation of the hub during fan operation.
Serious injury may result. Consult a qualified installer if in any
doubt about installation procedures.
Step 4.2: Fan Assembly Down Rod Version
Follow the instructions below for
installation of down rod ceiling fan.
1. Remove mounting bracket (#1) from
mounting cone.(#3) Leave the screws in
the bracket that match up with the open
hole on each side of mounting cone.
2. Attach mounting bracket to junction
box or directly to ceiling using screws
taped to mounting bracket.
Lead wires through center hole in
bracket.
3. Remove the four screws (#04) holding
the mounting cone (#3) to top of fan.
Remove cone from top of fan.
4. Put down rod (#07) through mount
cone (pivot ball (#05)end of rod remains
in cone).
5. Feed wires from receptacle through
bottom of down rod (#07) and out
through the pivot ball end.
41228-01 12/95
- 2 -
©1995 HUNTER FAN CO.™
16. Turn on power, and check that motor
shaft is turning in a counter clockwise
direction.
Turn power off.
17. Assemble blade arm (#22) and fan
blades (#21) using the 15 screws and
washers (#20) that are in bag with blade
arms.
18. Once the blades and arms are
assembled, attach the assemblies to the
hub using the bag of 10 screws (#16).
The inside hole pattern on the hub is
for four (4) blades.
The outside hole pattern on the hub is
for five (5) blades.
19. Turn on your fan
For more information:
Nextek Power Systems
Tel: 313.887.1321
www.nextekpower.com
461 Burroughs Street
Toll free: 1 (877) 24-VOLTS
Detroit, Michigan 48202
Fax: 313.887.9433
For more information:
Nextek Power Systems
Tel: 313.887.1321
www.nextekpower.com
461 Burroughs Street
Toll free: 1 (877) 24-VOLTS
Detroit, Michigan 48202
Fax: 313.887.9433
|
Installation Instructions For Vari-Fan Ceiling Fans
Installation Instructions For Vari-Fan Ceiling Fans
|
12. Push retaining knob (#18) onto motor
shaft until it is firmly against the hub.
13. Lift completed motor and hub assembly
to mounting bracket on ceiling, and slip
one hole on side of mounting cone over
hook on bracket.
14. With motor and assembly hanging from
hook, connect fan wires to the house
wires using three (3) wire nuts included
with fan. Fan should only be operated in
a counter-clockwise direction. Connect
white wire of fan to the negative power
house wire and the black wire of the fan
to the positive power house wire. The
green wire should be connected to the
ground wire on the mounting bracket.
15. After wires are connected, remove
fan from hook, and slip mounting cone
over mounting bracket. Align the open
holes of cone with the two screws, and
rotate until cone will stay in place. Then
replace the other two screws in cone
and tighten all four screws firmly.
6
7
6. Remove retaining pin and retaining clip
(#08) from receptacle.
7. Slip down rod into receptacle, and align
holes of rod with hole in receptacle.
8. Re-insert pin through receptacle/down
rod assembly and attach clip.
9. Tighten screw on side of receptacle.
10. Align the hub (#14) with the motor
shaft (#13). Align the flat side of the
motor shaft to the Allen Screw hole.
Push hub onto shaft until 3/8” (1cm) of
the shaft protrudes from the hub.
Tighten set screw using Allan Wrench
included with fan.
IMPORTANT:
To prevent wobble, make sure the FLAT of the motor
shaft is aligned with the FLAT of the center of hub. The set screw
should be tightened against the center of the FLAT of the motor
shaft.
11. Push retaining clip (#17) onto motor
shaft unit until it is firmly against the
hub.
WARNING:
Failure to install the retain clip tightly against the hub
as described may cause separation of the hub during fan operation.
Serious injury may result. Consult a qualified installer if in any
doubt about installation procedures.
Step 4.2: Fan Assembly Down Rod Version
Follow the instructions below for
installation of down rod ceiling fan.
1. Remove mounting bracket (#1) from
mounting cone.(#3) Leave the screws in
the bracket that match up with the open
hole on each side of mounting cone.
2. Attach mounting bracket to junction
box or directly to ceiling using screws
taped to mounting bracket.
Lead wires through center hole in
bracket.
3. Remove the four screws (#04) holding
the mounting cone (#3) to top of fan.
Remove cone from top of fan.
4. Put down rod (#07) through mount
cone (pivot ball (#05)end of rod remains
in cone).
5. Feed wires from receptacle through
bottom of down rod (#07) and out
through the pivot ball end.
41228-01 12/95
- 2 -
©1995 HUNTER FAN CO.™
16. Turn on power, and check that motor
shaft is turning in a counter clockwise
direction.
Turn power off.
17. Assemble blade arm (#22) and fan
blades (#21) using the 15 screws and
washers (#20) that are in bag with blade
arms.
18. Once the blades and arms are
assembled, attach the assemblies to the
hub using the bag of 10 screws (#16).
The inside hole pattern on the hub is
for four (4) blades.
The outside hole pattern on the hub is
for five (5) blades.
19. Turn on your fan