5
6
5 - SETTING THE TIMED ON
This process is used to set the time for which the Leds stays on before an automatic switch off.
NOTE: don’t use this process with HB70-SLCT, HB70-SPCT and TOUCH-1SP, the controller already has a procedure to
setting the automatic switch off of the light.
PROCEDURE
STEP 1
With a paper clip makes a short press
of the “hidden” button.
The led turns on.
MAKE A SHORT PRESS
THE LED TURNS ON
STEP 2
Within 10 seconds makes a short press of button 1.
The led start to flashes.
Each flash corresponds to a different timing.
LED START TO
FLASHES
MAKE A
SHORT PRESS
STEP 3
Makes a short press of button 1 while it is
flashing to end the count.
The led turns off
THE LED
TURNS OFF
MAKE A SHORT PRESS
DURING THE FLASHES
1
2
3
4
5
6
7
8
1 minute
3 minutes
5 minutes
15 minutes
30 minutes
1 hour
18 hours
No timed on
FLASHES
TIMED ON
6 - SELECTION OF TYPE OF LOAD CONNECTED
Default: RGB mode
This procedure is used to set up the type of control of load.
The three types are:
1 - RGB: in this case to create white light the control unit will use the three output channels "R", “G” and “B”
2 - RGBW modo 1: in this case to create white light the control unit will use the output channel "W"
3 - RGBW modo 2: in this case to create white light the control unit will use the output channel "W" and the three output
channels "R", “G” and “B”. This is to obtain the maximum available light.
PROCEDURE
STEP 1
With a paper clip makes a short press
of the “hidden” button.
The led turns on.
MAKE A SHORT PRESS
THE LED TURNS ON
STEP 2
Within 10 seconds makes a short press of button 2.
The led start to flashes.
Each flash corresponds to a different timing.
LED START TO
FLASHES
MAKE A
SHORT PRESS
STEP 3
Makes a short press of button 1 while it is
flashing to end the count.
The led turns off
THE LED
TURNS OFF
MAKE A SHORT PRESS
DURING THE FLASHES
1
2
3
RGB
RGBW mode 1
RGBW mode 2
FLASHES
TIMED ON