![Next Victor NM-II 3.2KW 24V PF1 User Manual Download Page 17](http://html1.mh-extra.com/html/next/victor-nm-ii-3-2kw-24v-pf1/victor-nm-ii-3-2kw-24v-pf1_user-manual_1683451017.webp)
02
Maximum charging
current: To configure
total charging current
for solar and utility
chargers.
(Max. charging current
= utility charging
c solar charging
current)
Available options in 3KVA model:
10A
20A
30A
40A (default for MPPT model)
50A (default for PWM model)
60A
70A (only for PWM model)
Available options in 3KW/5KW
model:
10A
20A
30A
40A
50A (default for PWM model)
60A (default for MPPT model)
70A
80A
90A
100A
110A
120A (Only for MPPT model)
03
AC input voltage range
Appliances (default)
If selected, acceptable AC input voltage
range will be within 90-280VAC.
UPS
If selected, acceptable AC input voltage
range will be within 170-280VAC.
05
Battery type
AGM (default)
Flooded
User-Defined
If “User-Defined” is selected, battery
charge voltage and low DC cut-off
voltage can be set up in program 26, 27
and 29.
15