- 4 - 

cabinet shape, size and rigging arrangements are totally compatible with the PXH64. To 

achieve the highest possible sound pressure levels, the PXL118 was conceived with a hybrid 
bass horn driven by a very powerful long excursion 18” driver with a 100mm voice coil, for 

precise and powerful bass without any dynamic loss even under high SPL output. 
 

 

CABLE

 

SELECTING

 

 

 

Selecting a cable consists of calculating the correct cable section (size) in relation to 

the load impedance and the required cable length. A small cable section will increase its 
serial resistance, which will induce power-loss and response variations (damping factor).  
 

The following table indicates, for 3 common sizes, a cable length with a maximum 

serial resistance equal to 4% of the load impedance (damping factor = 25): 
 
 

Cable section 

Maximum Length related to load impedance 

 

4

 

1.5 mm² 

12 m [40 ft] 

6 m [20 ft] 

2.5 mm² 

20 m [64 ft] 

10 m [32 ft] 

4 mm² 

32 m [104 ft] 

16 m [52 ft] 

 

CONNECTION

 

AND

 

ELECTRIC

 

DIAGRAM

 

 

 

 

The PXL118 is connected through Neutrik® Speakon® NL8FC plugs (not supplied). A 

wiring description is printed on the connections panels located on back of the cabinet. 

 
 

 

 

 

Summary of Contents for PXL118

Page 1: ...USER MANUAL PXL118 PX System Professional Subwoofer...

Page 2: ...oaudio com 1 V052013 Content INTRODUCTION 2 SAFETY FIRST 2 UNPACKING 3 PXL118 OVERVIEW 3 CABLE SELECTING 4 CONNECTION AND ELECTRIC DIAGRAM 4 AMPLIFICATION 5 TROUBLESHOOTING 6 TECHNICAL SPECIFICATIONS...

Page 3: ...high sound pressure levels and should be used with care Hearing loss is cumulative and can result from levels above 90dB if people are exposed for a long period Never stand close to loudspeakers drive...

Page 4: ...g equipment installation Failure to comply with these instructions may result on injury or death UNPACKING Each NEXT PX system component is built in Europe Portugal by NEXT Proaudio to the highest sta...

Page 5: ...ze in relation to the load impedance and the required cable length A small cable section will increase its serial resistance which will induce power loss and response variations damping factor The fol...

Page 6: ...scription 1 Sub 1 POS 1 Sub 1 GND 2 Sub 2 POS 2 Sub 2 GND 3 PXH64 Reserved 3 PXH64 Reserved 4 PXH64 Reserved 4 PXH64 Reserved Electric Diagram AMPLIFICATION The PXL118 sub woofers are designed to be u...

Page 7: ...he amplifiers last after the mixer and control electronics have stabilised When powering down the system reverse the sequence and switch off the amplifiers first TROUBLESHOOTING Simple troubleshooting...

Page 8: ...Maximum SPL calculated 135dB Frequency Response 10dB 32Hz 180Hz Crossover Frequency active LP 150Hz 24dB Oct L R Components 1 x 18 Subwoofer Connectors 2 x Parallel Neutrik NL8 Enclosure Material 15mm...

Page 9: ...defects caused by unauthorized modifications improper use negligence exposure to inclement weather conditions act of God or accident or any use of this product that is not in accordance with the inst...

Page 10: ...ONTACTS In case of any doubts or any information just Write us NEXT PROAUDIO Rua da Venda Nova 295 4435 469 Rio Tinto Portugal Contact us Tel 351 22 489 00 75 Fax 351 22 480 50 97 Send an e mail info...

Reviews: