NEXT
PFA
12/
PFA
12p
- User Manual
www.next-proaudio.com
- 5 -
PFA12 Preset List:
0- Flat: Flat frequency response
1- Music: Frequency response adapted for music reproduction (SPL level boosted at low frequencies
and ear compensation, due to high SPL levels, at the mid-high frequency range)
2- Vocal: Frequency response adapted for voice speech (High Pass Filter at 90Hz and EQing for an
improved intelligibility
3- Horiz. Coupled: Frequency response adapted for the sound reproduction with two units, one very
next to the other (Low Shelf Filter to compensate the bass coupling)
4- Satellite (Flat): Flat frequency response when playing with a subwoofer (High Pass Filter at 100Hz
24dB/Oct Linkwitz-Riley)
5- Satellite (Music): Frequency response adapted for music reproduction when playing with a
subwoofer (High Pass Filter at 100Hz 24dB/Oct Linkwitz-Riley and ear compensation, due to high
SPL levels, at the mid-high frequency range)
6 / 7- User Defined: Free memory for user storage (Customized preset can be saved on this memory
positon)
PFA12p
The PFA12p is the passive version (8
Ω
)
of the PFA12.
Able to deliver an extremely high output and dynamics for its
size, extreme linearity and fidelity, is one of the best solutions in
terms of price/quality ratio in the market. PFA12p is provided
with a passive crossover precisely calculated and optimized for
the best frequency and phase response. It is recommended to
use a 24dB/Oct Linkwitz-Riley high pass filter at 60Hz. When
used with the PFA18s subwoofer it becomes the perfect
solution for any kind of audio reinforcement and reproduction.