CONNECTIONS AND ELECTRIC DIAGRAM
The LAs118
v2
is connected through Neutrik® SpeakON® NL4 plugs (not supplied). A wiring description is
printed on the connections panels located on the back of the cabinet.
The 4 pins of the two Neutrik® NL4 SpeakON® sockets are wired in parallel within the enclosure. Either
connector can be used to connect to the amplifier or another LAs118
v2
element. See the table and the diagram
below:
NL4 PIN
Description
1+
LOW +
1-
LOW -
2+
LINK +
2-
LINK -
CABLE SELECTING
Selecting a cable consists of calculating the correct cable section (size) in relation to the load impedance
and the required cable length. A small cable section will increase its serial resistance, which will induce power-
loss and response variations (damping factor).
The following table indicates, for 3 common sizes, a cable length with a maximum serial resistance equal to
4% of the load impedance (damping factor = 25):
Cable section
Maximum Length related to load impedance
8Ω
4Ω
1.5 mm²
12m [40 ft]
6m [20 ft]
2.5 mm²
20m [64 ft]
10m [32 ft]
4 mm²
32m [104 ft]
16m [52 ft]