4.3 Limita ons
• No vibra on genera ng devices (except tac le transducers) can be at-
tached to the top frame.
• Maximum allowable total weight of scale tac le transducer a ached
to the cockpit: 2.3 kg (5.0 lbs)
• The top frame movements cannot be limited by any obstacles.
• Seat belts and harness tensioners must NOT be a ached to any sta c
part of the mo on pla orm or floor.
• Maximum allowed number of tac le transducer a ached to cockpit is
3.
4.4 Built-in Power Supply Specifica on
• Ac ve PFC func on, PF > 0.95
• Protec ons: short circuit, overload, over voltage, over temperature
• Safety standards: UL60950-1, TUV EN60950-1, EAC TP TC 004, CCC
GB4943.1, BSMI CNS14336-1, AS/NZS 60950.1
• Withstand voltage: I/P-O/P:3KVAC, I/P-FG:1.5KVAC, O/P-FG:0.5KVAC
• Isolate resistance: I/P-O/P, I/P-FG, O/P-FG: 100MOhms/500VDC/25C/70% RH
• EMC emission: Compliance to EN55032 (CISPR32) Class B, EN61000-3-
2,-3, EAC TP TC 020, CNS13438, GB9254 Class B, GB17625.1
• EMC immunity: Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204,
EN55024, light industry level, criteria A, EAC TP TC 020
Product Manual
8