ERIES HARDWARE SETUP PROCEDURE
Horizontal (PS15R2 only)
•
Remove the four TORX screws holding connector plates on both side of PS15R2;
•
Remove the connector plates from PS15R2;
•
Fill each screw hole with Locktite 243 or equivalent;
•
Position external plates from VNI-LBRK kits and secure them using the shoulder screws
supplied with these kits;
•
Position “L” brackets from VNI-LBRK kits, and secure them to the cabinet using the 4 remaining
shoulder screws supplied with these kits.
•
Slings and shackles (not provided) are required to secure the cluster under the ceiling;
CABLE SUSPENSION MOUNTING PROCEDURE FOR PS15R2
7.3.4 PS10R2 and PD15R2 wall suspension (vertical or horizontal)
Required item
Vertical
•
1 VNI-WS10 for PS10R2
•
1 VNI-WS15 for PS15R2
•
4 x 12mm diameter screws (
not provided
)
Horizontal
•
1 VNI-WS10 and 1 VNI-UBRK10 for PS10R2
•
1 VNI-WS15 and 1 VNI-UBRK12 for PS15R2
•
4 x 12mm diameter screws (
not provided
)
IMPORTANT
Ensure that the wall is strong enough to hold PS cabinet weight and that the screws
12mm diameter and corresponding plugs required to fix the VNI-WS on the wall are
properly dimensioned.