background image

ACCESSORIES

 

 

 

P12

 

Page 

11

 / 

18

 

PNT-WMADAPT 

 

With PNI-WMxxx & PNT-BUMP 

 

With PNT-BUMP 

 

PNI-CLADAPT 

Ceiling Adapter, use with HBRK12, VBRK12. 

 

PNI-WM330 

Wallmount for P12, with WMADAPT 

 

Summary of Contents for P12

Page 1: ...DP3946 01 DI P12 User manual ...

Page 2: ...9 ACCESSORIES ________________________________________________________________________ 10 ARRAY EQ____________________________________________________________________________ 12 MAINTENANCE ________________________________________________________________________ 13 TECHNICAL SPECIFICATIONS ___________________________________________________________ 16 USER NOTES ___________________________________...

Page 3: ... accidentally If the system is used on a tripod please ensure the tripod s specifications are adapted and that its height does not exceed 1 40m 55 Do not move the tripod with the system in position Connection and Powering Precautions Unplug connected cables before moving the system Power off the system before connecting the system When switching on the installation the amplifier must be powered la...

Page 4: ...EQUIPMENT Page 4 18 P12 EQUIPMENT 3 locations for hanging 1 on the back and on both side On the sides you ll find a print for speaker stand 3 locations for connecting on the back and on both side ...

Page 5: ...r of 35mm IMPORTANT Speaker stand must be rated for P12 weight Speaker stand must always be installed on a horizontal surface Stand height and footprint must be defined to prevent assembly from collapsing Ensure that audience is not allowed within a safety area which radius is equal or higher than assembly height Test steadiness of the assembly by pushing in all directions ...

Page 6: ... the sub ACTIVE MODE LF 1 1 HF 2 2 Amplification The P12 speakers must be used with a NEXO processor to handle EQ phase alignment crossover and excursion thermal protection for the system loudspeaker There are two NEXO processor series supporting the P12 speakers NXAMP 4 channels amplified processors and DTD processors stereo sub DTD processors ensure optimal performances when used with DTDAMP pow...

Page 7: ...z P12 MAIN PA PSguide with high pass at 60 or 85 Hz Active Mode WARNING Do not mix directivity and or modes P12 MON HF 6060 with P12 MON LF 6060 OK P12 MAIN HF 6060 with P12 MON LF 6060 NOT OK P12 MON HF 9040 with P12 MON LF 6060 NOT OK P12 MON HF 6060 with high pass at 60 or 85 Hz P12 MON HF 9040 with high pass at 60 or 85 Hz P12 MON HF PSguide with high pass at 60 or 85 Hz P12 MON LF 6060 with h...

Page 8: ...PRESET Page 8 18 P12 P12 Sub Stage monitor applications with Subs OMNI or CARDIO modes Front of house applications with Subs OMNI or CARDIO modes ...

Page 9: ...otation allow to deal with every request 1 Unlock the 2 quarter turn screws Remove the grille 2 Remove the 4 HF Cap and store them 3 Place the flange if necessary rotate it 4 Magnets keep the flange in place When replacing the grille ensure it is well positioned in the top blade before fasten with quarter turn screws CROSSOVER FREQUENCY 60 Hz Full range application 85 Hz Use as front fill on stage...

Page 10: ... ones provided by NEXO NEXO will decline responsibility over the entire P12 accessory range if any component is purchased from different supplier PROHIBITED P12 below P12 or P12 below L15 without dedicated accessory PNT BUMP LiftBar for P12 use with P12 WMADAPT PNT HBRK12 Horizontal Cradle use with CLADAPT PLADAPT PNT PLADAPT Pole Adapter use with P12 HBRK12 VBRK12 PNT VBRK12 Vertical Cradle use w...

Page 11: ...ACCESSORIES P12 Page 11 18 PNT WMADAPT With PNI WMxxx PNT BUMP With PNT BUMP PNI CLADAPT Ceiling Adapter use with HBRK12 VBRK12 PNI WM330 Wallmount for P12 with WMADAPT ...

Page 12: ...FLG9040 Flange dispersion adapter 90 40 PNT 2CASE12 FLIGHT CASE FOR 2X P12 PNT ACC12 FLIGHT CASE FOR P12 ACCESSORIES PNT COV12 COVER FOR P12 ARRAY EQ The ArrayEQ allows to adjust the system frequency response in its lower range see curves below with different ArrayEq values ...

Page 13: ...Page 13 18 MAINTENANCE Driver access 1 Unlock the 2 quarter turn screws Remove the grille 2 Remove 8 screws 3 Remove the stickers 4 Remove the 2 screws 5 Remove the horn 6 To access to the HF diaphragm remove 4 screws ...

Page 14: ...MAINTENANCE Page 14 18 P12 CNX access Remove the screws of the connector inside the handles Remove the screws of the CNX 6 and of the Passive filter 4 Unplug the CNX from the passive filter ...

Page 15: ...grille Touring Black with fasteners 1 05P12UA PW Complete grille Touring White with fasteners 3 2 05SPK01 Speakon NL4 complete with screws 4 1 05CNXP01 CNX complete Black with screws 1 05CNXP01 PW CNX complete White with screws 5 1 05NHP12R K HF diaphragm with screws 6 1 05HPC12 P12 driver complete with screws 1 05HPC12R K Recone Kit 12 with screws ...

Page 16: ...r Frequency 60Hz 85 Hz Nominal Impedance Active mode 8Ω LF 8Ω HF Passive mode 8Ω SPECIFICATIONS Model P12 Components LF 1x12 8Ω HF 1x 3 8Ω Neodymium driver Material Baltic birch Poplar plywood Finish Black or white structural paint Front finish Steel front grille Back mesh Fittings Handle on both sides Threated inserts on the back and on both sides for connection of mounting accessories Stand fitt...

Page 17: ...USER NOTES P12 Page 17 18 USER NOTES ...

Page 18: ...Page 18 18 P12 NEXO S A F 60128 PLAILLY Tel 33 3 44 99 00 70 Fax 33 3 44 99 00 30 E mail info nexo fr nexo sa com ...

Reviews: