Page 48/63
T
ECHNICAL
S
PECIFICATIONS
6.2 GEO T2815 Vertical Tangent Array Module
6.2.1 System
specifications
PRODUCT FEATURES
GEO T2815
Components
HF: 1 x 3” voice coil, 1.4” throat neodymium 16 Ohm driver on an hyperboloid reflective wavesource.
MF/LF: 2 x 8” (20cm) long excursion neodymium hi-flux 16 Ohm drivers in series.
Rear Passive Acoustic Resistor
Height x Width x Depth
249 x 903 x 537 mm (9 13/16” x 35 1/2” x 21 1/8”) including array assembly system
Shape 15°
Trapezoid.
Weight: net
29 kg (63.9 lbs) including array assembly system.
Connectors
1 x AMPHENOL EP6 6 pole socket In; 1 x AMPHENOL AP6 6 pole connector Through.
Construction
Main structure: Baltic birch ply with structured black coating. Rear section: Aluminum with dark grey coating.
Front finish
Injected polyurethane flange, metallic gray coating (structured black on request).
Flying points
Integral flying system.
Intercabinet angle adjustments = 6.30°, 8.00°, 10.0°, 12.5°, 15° (logarithmic steps)
SYSTEM SPECIFICATIONS
GEO T2815 with NX242 TDcontroller
Frequency response [a]
85 Hz – 19 kHz ± 3 dB
Usable range @-6dB [a]
77 Hz – 20 kHz
Sensitivity 1W @ 1m [b]
107 dB SPL nominal (105 dB SPL wideband)
Peak SPL @ 1m [b]
Configuration dependent [d].
Dispersion [c]
Vertical plane: Configuration dependent [d].
Horizontal plane: 120°.
Low Frequency: cardioid
Crossover frequencies
LF/MF-HF: 1.3 kHz active
Nominal impedance
HF: 16 Ohm; LF/MF: 32 Ohm
Recommended amplifiers
HF: 2700 Watts into ~3 Ohm (6 cabinets parallel per amp channel).
MF/LF: 5200 Watts into ~6 Ohm (6 cabinets parallel per bridged mono amp).
SYSTEM OPERATION
Electronic controller
The NX242 Digital TDcontroller presets are precisely matched to the GEO T Series cabinets and include sophisticated
protection systems as well as advanced cardioid directivity DSP algorithms. Using GEO T Series cabinets without a
properly connected NX242 will result in poor sound quality and can damage components.
Array design
Arrays of less than 4 x GEO T2815 will provide poor dispersion control and are neither recommended nor supported.
Sub-bass
CD18 directional sub extends system low frequency response down to 25 Hz
Speaker cables
HF: wired 5(-) / 6(+).
MF/LF: wired 3(-) / 4(+).
1(-) / 2(+) not connected (through).
Rigging System
Please refer to the GEO user manual before any operation.
As part of a policy of continual improvement, NEXO reserves the right to change specifications without notice.
[a]
Response curves and data: anechoic far field above 200 Hz, half-space anechoic below 200 Hz.
[b]
Sensitivity & peak SPL: will depend on spectral distribution. Measured with band limited pink noise.
Refers to the spe/- 3 dB range. Data are for s pro recommended amplifier combinations.
[c]
Directivity curves and data: 1/3 octave smoothed frequency response, normalized to on-axis response. Data obtained by computer processing of off-axis
response curves.
[d]
Please refer to the GEO T user Manual.
Usable range data: frequency response capability with TD crossover slopes removed.
Summary of Contents for GEO T Series CD18
Page 57: ...CONNECTION DIAGRAMS Page 57 63 7 2 CD18 to amplifiers and NX242 ...
Page 61: ...USER NOTES Page 61 63 10 USER NOTES ...
Page 63: ......
Page 64: ......
Page 65: ......
Page 66: ......
Page 67: ......