T
ECHNICAL
S
PECIFICATIONS
Page
75/93
9
T
ECHNICAL
S
PECIFICATIONS
9.1 GEO D10 Vertical Tangent Array Module
9.1.1 System
specifications
PRODUCT FEATURES
GEO D10
Components
HF: 1 x 3” voice coil, 1.4” throat 16 Ohms driver on a 5° hyperboloid reflective wavesource.
MF/LF (front-firing): 1 x 12” (30cm) high excursion neodymium 16 Ohm driver.
LF (side-firing): 2 x 8” (20cm) neodymium 8 Ohm drivers in series.
Height x Width x Depth
380 x 744 x 750 mm (15” x 29
1/3
” x 29
1/2
”) including array assembly system
Rigging axis to axis height: 344mm (13
1/2
”)
Shape 10°
Trapezoid.
Weight: net
57 kg (125.7 lbs) including array assembly system.
Connectors
1 x AMPHENOL EP6 6 pole socket In; 1 x AMPHENOL AP6 6 pole connector Through.
Construction
Baltic birch ply with structured black coating.
Front finish
Molded Dark Grey Metal Grill.
Flying points
Integral flying system.
Intercabinet angle adjustments = 0.2°, 0.315°, 0.5°, 0.8°; 1.25°, 2.0°, 3.15°, 5°, 6.3°, 8.0°, 10.0° (logarithmic steps)
SYSTEM SPECIFICATIONS
GEO D10 with NX242 Tdcontroller & NX-tension Card
Frequency response [a]
60 Hz – 19 kHz ± 3 dB
Usable range @-6dB [a]
55 Hz – 20 kHz
Sensitivity 1W @ 1m [b]
105 dB SPL nominal (103 dB SPL wideband)
Peak SPL @ 1m [b]
Configuration dependent [d].
Dispersion [c]
Vertical plane: Configuration dependent [d].
Horizontal plane: Configurable 80° / 120°.
Low Frequency: cardioid
Crossover frequencies
LF-MF: 300 Hz active; MF-HF: 1.1 kHz Passive or Active (internally configurable)
Nominal impedance
HF: 16 Ohm; LF/MF front: 16 Ohm; LF rear: 16 Ohm
Recommended amplifiers
3 GEO D10 in Parallel
HF: 875 to 1550 Watts into 4 Ohms
MF/LF front: 1750 to 3100 Watts into 4 Ohms
LF rear section: 1750 to 3100 Watts into 4 Ohms
4 GEO D10 in parallel
HF: 1000 to 1800 Watts into 4 Ohms
MF/LF front: 2000 to 3600 Watts into 4 Ohms
LF rear section: 2000 to 3600 Watts into 4 Ohms
6 GEO D10 in parallel
HF: 1650 to 3000 Watts into 2 Ohms
MF/LF front: 3300 to 6000 Watts Watts into 2 Ohms
LF rear section: 3300 to 6000 Watts Watts into 2 Ohms
SYSTEM OPERATION
Electronic controller
The NX242 Digital TDcontroller (with NX-Tension Card) presets are precisely matched to the GEO D Series cabinets
and include sophisticated protection systems as well as advanced cardioid directivity DSP algorithms. Using GEO D
Series cabinets without a properly connected NX242 & NX-Tension Card will result in poor sound quality and can
damage components.
Array design
Arrays of less than 4 x GEO D10 will provide poor dispersion control and are neither recommended nor supported.
Sub-bass
GEO SUB directional sub extends system low frequency response down to 35 Hz
Speaker cables
Active: 5(-) / 6(+): HF; 3(-) / 4(+):LF/MF Front ; 1(-) / 2(+): LF Rear.
Passive: 5(-) / 6(+): Not Connected; 3(-) / 4(+):LF/MF/HF Front ; 1(-) / 2(+): LF Rear..
Rigging System
Please refer to the GEO user manual before any operation.
As part of a policy of continual improvement, NEXO reserves the right to change specifications without notice.
[a]
Response curves and data: anechoic far field above 200 Hz, half-space anechoic below 200 Hz.
[b]
Sensitivity & peak SPL: will depend on spectral distribution. Measured with band limited pink noise.
Refers to the spe/- 3 dB range. Data are for s pro recommended amplifier combinations.
[c]
Directivity curves and data: 1/3 octave smoothed frequency response, normalized to on-axis response. Data obtained by computer processing of off-axis
response curves.
[d]
Please refer to the GEO D user Manual.
Usable range data: frequency response capability with TD crossover slopes removed.