Xperience platform
All of Nexmosphere’s controllers are built on the same platform principles. If this is your first time using a Nexmosphere
controller, we recommend to first read
https://nexmosphere.com/technology/xperience-platform/
to learn the basics about
our platform and its terminology.
XC-820
The XC-820 is an Xperience controller with 4 X-talk interfaces and
2 RGBW LED Outputs:
1.
X-talk interface 001
2.
X-talk interface 002
3.
X-talk interface 003
4.
X-talk interface 004
A.
RGBW LED output A (Generic API address 005, RGBW channel A)
B.
RGBW LED output B (Generic API address 005, RGBW channel B)
USB.
API interface (micro-USB connector)
LED.
White status LED
DC.
12-24VDC Power input (2.1mm DC socket)
Hardware setup
1.
Connect one or more Elements to any of the 4 X-talk interfaces.
2.
Connect one or more RGB(W) LED strips to any of the 2 RGBW LED outputs*.
3.
Connect the 12 or 24VDC power supply to the DC power input connector. Make sure the voltage of the power supply
matches the operating voltage of the RGBW LED strips (12VDC or 24VDC).
4.
Connect the micro-USB cable to a 3rd party device (e.g. Digital Signage Player or PC).
5.
Wait until the white status LED stops blinking. This lasts about 5 seconds.
*
RGBW LED strips including connection cable are available as an accessory (product codes L-X5.....l). If you want to connect your own RGBW LED strips, separate
connection cables are also available as an accessory (product codes CA5-S..C).
Software setup for testing (Terminal)
Typically, the XC-820 controller is connected to a 3rd party device, such as a Digital Signage Player, on which CMS software is installed that has built-in
functionality for sending and receiving Serial Events. However, if you want to do a first test on a PC or Mac, follow the instructions below:
1.
Download a terminal program. For example
or
2.
Open the Terminal program and go to settings. Choose the COM port on which the XC-820 controller enumerated*.
In most cases this is the highest available number in the COM port drop-down setting.
3.
Set the COM port settings to the following values
Baudrate
115200
Flow Control
None
Parity
None
EOL
CR+LF
Data
Bits 8
Protocol
ASCII
Stop
Bits 1
4.
Set the COM port to “Open”.
The controller is now ready for use.
5.
When sending consecutive API serial commands to the XC-820 controller, place a 50mS delay between each command.
*
In case the XC-820 controller is not recognized as a COM port by the 3rd party device, a driver (Prolific PL2303) can be downloaded
N ex m o s p h e re
H i g h Te c h C a m p u s 1 0 ( M μ b u i l d i n g )
5 6 5 6 A E E i n d h ove n • T h e N e t h e r l a n d s
T
+ 3 1 4 0 2 4 0 7 0 7 0
E
s u p p o r t @ n ex m o s p h e re.c o m
QUICK START GUIDE
XC-820 XPERIENCE CONTROLLER
© 2020 Nexmosphere. All rights reserved. v1.0 / 07-20
All content contained herein is subject to change without prior notice.
1
USB
DC
LED
5
6
A
B
XC
4
5
5
2
3
1