4
FORM NO. L-20113-E-0501
ELECTRICAL CONNECTIONS
1.
Remove the cover from the EN40-IS and remove the
WARNING Tag from the INPUT terminals (See
Figure 7).
CAUTION
Always short the INPUT terminals when
transporting or storing the EN40-IS.
2.
Using customer supplied 18AWG wire, connect
EN40-IS to Zenier Barrier, routing wire through
threaded conduit hole on side of EN40-IS.
3.
Connect the EN40-IS Ground to a suitable ground.
CAUTION
Always observe the polarity of the
EN40-IS terminals. The Driving Design
is the logic diagram used with the
TC240-IS System (See Figure 8). If the
TC240-IS is not used, refer to the
Sinking Design (See Figure 9).
Remove
WARNING
Tag
FIGURE 7
FIGURE 8
Driving Design
FIGURE 9
Sinking Design
®