3. INSTALLATION LOCATIONS
Recommended locations in a domestic or tertiary environment
It is recommended to install the monitor:
- Less than 1 meter above the ground if the monitor is placed on an item of furniture or a shelf (using the mobile
mounting base delivered with Carbon)
- Less than 1.5 meters above the ground if the monitor is wall mounted (attached with screws and wall plugs)
In order to obtain accurate and reliable data, we suggest you to follow recommended locations
Locations to avoid
Do not install the indoor air quality monitor:
- Less than 30 cm from the ceiling
- Outdoors
- In a location where the temperature is less than 0°C or more than 50°C
- In a location where humidity levels is more than 95% (bathroom, kitchen, laundry room, etc.)
- In a dusty or dirty location (garage, workshop, etc.)
- Less than 1 m from doors and windows, heating, cooling or air vents
- In a narrow area where the monitor could be damaged
- In a contained location (e.g. in a cupboard or behind a curtain)
- In a location where the monitor could be blocked (e.g. by furniture)
4. COMMISSIONING THE MONITOR
To commission your monitor, activate the single-use
switch (1).
Confirmation of product activation is indicated by a
flashing of the green-orange-red LED for 10 seconds.
Then, the green LED flashes about every 20 seconds
during the initializing period hat may last up to 2
minutes. The end of this initializing period is
represented by the continuous lighting of the green
LED for 5 seconds.