Copyright © 2015 NEXCOM International Co., Ltd. All Rights Reserved.
73
NISE 3700E Series User Manual
Appendix A: Power Consumption
Power Consumption Management
Purpose
The purpose of the power consumption test is to verify the power dissipation
of system, and the loading of power supply.
Test Equipment
1. GWInstek PSW 80-40.5 DC power supply.
2. Windows 7 x32 Pro Operating System
3. Burn In Test Ver7.1
4. Kpower Software.
5. Network test program.
6. USB 2.0 (5V, 0.5A(Cement Resistor))*4.
7. USB 3.0 (5V, 1.0A(Cement Resistor))*4.
device Under Test
DUT: sys#1/
Test Procedure
1. Use Device Manager to examine devices.
2. Use DC power supply to measure the power consumption.
3. Measure system maximum power consumption in the modes below:
S3 mode.
Idle mode.
Full loading mode (Include USB load fixture).
4. Record the power usage (in watts).
Test data
Sys #1
(Disabled Turbo Boost)
+24V
Full-Loading Mode
2.98A
Total
71.52W
Standby S3 Mode
0.063A
Total
1.51W