Chapter 1: Product Introduction
Power Requirement
▪
Power input: +9Vdc to +30Vdc
▪
1x optional 24V, 60W power adapter
dimensions
▪
NISE 2400: 191mm (W) x 200mm (D) x 60mm (H)
without wall-mount bracket
▪
NISE 2410/2410E: 195mm (W) x 200mm (D) x 90mm (H)
without wall-mount bracket
▪
NISE 2420: 195mm (W) x 200mm (D) x 111mm (H)
without wall-mount bracket
Construction
▪
Aluminum and metal chassis with fanless design
Environment
▪
Operating Temperature:
Ambient with air flow: -20°C to 70°C
(According to IEC60068-2-1, IEC60068-2-2, IEC60068-2-14)
▪
Storage temperature: -30°C to 85°C
▪
Relative humidity: 10% to 95% (non-condensing)
▪
Shock Protection:
– HDD: 20G, half sine, 11ms, IEC60068-2-27
– CFast: 50G, half sine, 11ms, IEC60068-2-27
▪
Vibration Protection w/ HDD Condition:
– Random: 0.5Grms @ 5 ~ 500Hz, IEC60068-2-64
– Sinusoidal: 0.5Grms @ 5 ~ 500Hz, IEC60068-2-6
▪
Vibration Protection w/ CFast & SSD Condition:
– Random: 2Grms @ 5 ~ 500Hz, IEC60068-2-64
– Sinusoidal: 2Grms @ 5 ~ 500Hz, IEC60068-2-6
Certifications
▪
CE
▪
FCC Class A
OS Support List
▪
Windows 8, 32-bit/64-bit
▪
Windows Embedded Standard 8, 32-bit/64-bit
▪
Windows 7, 32-bit/64-bit
▪
Windows Embedded Standard 7, 32-bit/64-bit
▪
Linux Kernel version 3.8.0
▪
Android 4.4, 64-bit
▪