12
Snow melting OFF temperature
When it is colder than this temperature the snow melting is switched OFF.
Snow melting air humidity min
When wireless outdoor temperature sensor is used the thermostat also
receives air humidity level. Snow melting function will not be activated if the
air humidity is below this limit.
User program activated eco temp
During all green hours in user program the temperature is adjusted to this
value.
Externally activated eco temp
When 230VAC (pilot signal) is connected to the setback input terminal the
desired temperature is defined by this parameter.
Valve protection
Valve protection turns heating ON once per week for 5 minutes even at summer
time. This setting is typically used with water carrier floor heating valves.
Feature prevents the valve from getting stuck during summer.
Sensor type
Floor sensors from different manufacturers can be used. Supported types
are 2k, 10k, 12.5k, 15k, 33k NTCs.