TECHNICAL DATA

A declaration of conformity is available online at www.nexa.se

MGDR-200
Power supply    

220-240 V~50 Hz

Max. load

200 W

Max. load LED

3-24 W LED

Protocol

System Nexa (433,92 MHz)

Range

up to 30 m

Memory slots 

32

Own consumption

< 1 W

IP classification

IP44

Dimensions

53 x 70mm

Plug-in receiver with dimmer function for earthed sockets. Works 

with System Nexa remote controls, transmitters and Nexa Bridge. 

The system is “self-learning”, which ensures extremely simple and 

flexible installation.  
INSTALLATION

  

Connect power to the receiver; make sure that the output does not 

exceed the output stated in the table under “Technical Data”.
PROGRAMMING

 

1. Connect the receiver (plug-in) to an electrical socket. The receiver 

will switch to programming mode as soon as current is applied. 

2. Press the “ON” button for the chosen channel on any System 

Nexa remote control within 6 seconds. 

CONFIRMATION OF PROGRAMMING 

The connected light will dim up and down two times.
DELETE MEMORY

 

1. To delete a memory slot, remove the receiver (plug-in) from the 

wall socket. 

2. Wait for at least 6 seconds. 

3. Replace the receiver in a wall socket. 

4. Press the “OFF” button for the selected channel on a System 

Nexa remote control within 6 seconds.  

To delete all memory slots, repeat steps 1–3 above and then press 

the “ALL OFF” button on the System Nexa remote control within 6 

seconds.
CONFIRMATION OF DELETION 

The connected light will dim up and down two times.
MEMORY 

Each MGDR-200 plug-in receiver has 32 memory slots. When all 32 

slots are full, slot 1 will be overwritten on new programming.
CONTROL 

The plug-in receive can be controlled in several ways.

1. With a System Nexa Remote Control

2. With other programmed System Nexa transmitters

3. With Nexa Smart Hub

4. With Nexa Bridge

THIS PRODUCT FEATURES SUPPORT FOR SMART MODE.

  

In units that support Smart Mode, up to 3 different favourite sce-

narios can be saved and then activated easily using a Nexa Smart 

Mode transmitter.

DIMMER SETTINGS 

The MGDR-200 is supplied set up for trailing edge phase dimming.
SETTING THE LOWEST DIMMER LEVEL  

1.  Remove the (plug-in) receiver from the wall socket. 
2.  Wait for at least 6 seconds. 
3.  Replace the receiver in a wall socket. 
4. Press the ON button on a programmed System Nexa remote 

control for 3 seconds within 6 seconds.

5. The connected light will dim up and down two times.
6. Use the programmed remote control to adjust the lowest dimmer 

level. ON increases the level one step, OFF reduces the level one 

step.  (Four steps in all)

7. Press the ON button on a programmed System Nexa remote 

control for 3 seconds to confirm the lowest dimmer level.

8. The connected light will dim up and down two times, and then 

dim down to the lowest level set to confirm the new setting.

MGDR-200

Plug-in Dimmer for outdoor use

NEXA AB, DATAVÄGEN 37B, 436 32 ASKIM, SWEDEN

[email protected]  |  www.nexa.se

ENGLISH

SAFETY AND INFORMATION 
Range indoors:

 

up to 30 m (optimal conditions). The range is 

heavily dependent on local conditions – such as if there are any 

metals nearby. For example, the heavy metal coating in low-

emission energy glass has a negative impact on the range of the 

radio signals. There may be limitations on the use of the unit outside 

the EU. If appropriate, check that the unit complies with the local 

regulations.

Max. load:

 Never connect lights or equipment that exceeds the 

maximum load of the receiver. This can result in faults, short circuit 

or fire.

Life-support equipment :

 Never use Nexa products for life support 

equipment or other devices where faults or disruptions can have 

life-threatening consequences.

Disruptions: 

All wireless units can be affected by disruptions that 

may have an impact on performance and range. The minimum 

distance between two receivers should therefore be at least 50 cm.

Repairs:

 Do not attempt to repair the product. It does not contain 

any serviceable parts.

Waterproofing:

 The product is in a flush-proof design (IP44). 

For proper outdoor function, the connected plug must be of an 
approved design for outdoor use (IP44).
Cleaning:

 Clean the product with a dry cloth. Do not use chemicals, 

solvents or potent cleaning agents.

Environment: 

Do not expose the product to extreme heat or cold, 

as this may damage the electronic circuits or shorten their service 

life.