background image

EDH0185En1020 — 07/11

vi

VP-25XA

Precision Compact Linear Stage

Definitions and Symbols

The  following  terms  and  symbols  are  used  in  this  documentation  and  also

appear on the product where safety-related issues occur.

General Warning or Caution

The  exclamation  symbol  may  appear  in  warning  and  caution  tables  in  this

document. This symbol designates an area where personal injury or damage

to the equipment is possible.

European Union CE Mark

The  presence  of  the  CE  Mark  on  Newport  Corporation  equipment  means

that  it  has  been  designed,  tested  and  certified  as  complying  with  all

applicable European Union (CE) regulations and recommendations.

ATTENTION

This  stage  is  a  Class  A  device.  In  a  residential  environment,
this device can cause radioelectric interferences. In this case,
suitable  measurements  must  be  taken  by  the  user  of  this
device.

0.1

Warnings and Cautions

The following are definitions of the Warnings, Cautions and Notes that may

be used in this manual to call attention to important information regarding

personal  safety,  safety  and  preservation  of  the  equipment,  or  important

tips.

WARNING

Situation has the potential to cause bodily harm or death.

CAUTION

Situation has the potential to cause damage to property or
equipment.

NOTE

Additional information the user or operator should consider.

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for VP-25XA

Page 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Page 2: ...Compact Linear Stage VP 25XA USER S MANUAL G U ARANTE E D S P E CIFICATIO N S RoHS Compliant For Motion Think Newport Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www arti...

Page 3: ...resulting from Incorrect usage Load on the stage greater than maximum specified load Carriage speed higher than specified speed Improper grounding Connectors must be properly secured When the load on...

Page 4: ...ristics and Stiffness 4 3 5 Stage Weight 4 4 0 Drive 5 5 0 Motor 5 5 1 DC Motor Characteristics 5 5 2 Command Signals for UE25CC DC Motor 5 5 3 Sensor Position 6 5 4 Feedback Signal Position 6 5 5 Pin...

Page 5: ...Stage 9 0 Assemblies 12 9 1 XY Mounting 12 9 2 XYZ Configuration 13 10 0 Maintenance 14 10 1 Maintenance 14 10 2 Repairing 14 10 3 Calibration 14 Service Form 15 Artisan Technology Group Quality Inst...

Page 6: ...ons of the Directive 2006 42 EC on machinery complies with all the relevant provisions of the Directive 2004 108 EC relating to electro magnetic compatibility was designed and built in accordance with...

Page 7: ...an Union CE regulations and recommendations ATTENTION This stage is a Class A device In a residential environment this device can cause radioelectric interferences In this case suitable measurements m...

Page 8: ...e motor power and then disconnect the electronics from power supply Contact your Newport service facility and request repairs WARNING Do not insert or drop objects into this stage this may cause an el...

Page 9: ...his stage if its motor power is on Make sure that the cable to the electronics is disconnected before moving the stage Failure to do so may damage the cable and cause an electrical shock CAUTION Be ca...

Page 10: ...rating instructions for the M VP 25XA precision compact linear stage VP 25XA translation stage RECOMMENDATION We recommend you read carefully the chapter Connection to electron ics before using the VP...

Page 11: ...ion controllers The VP 25XA stage is equipped with a cable of 1 5 m length and a 25 pin sub D connector for connection to our motion controllers 3 0 Characteristics 3 1 Definitions Specifications of o...

Page 12: ...interferometer A linear cycle with 21 measures on travel and 4 cycles in each direction gives a total of 164 points 3 2 Mechanical Specifications Resolution m 0 1 On Axis Accuracy m 2 Bi directional...

Page 13: ...r distance in millimeters Cz Normal center load capacity on bearings Cx Inverse load capacity on X axis Cx Direct load capacity on X axis k x Angular stiffness Roll k y Angular stiffness Pitch k z Ang...

Page 14: ...l is referred to Motor signal Tacho Generator signal is referred to Tacho Generator signal When the stage moves in Direction the Motor voltage is higher than Motor voltage and Tacho Generator voltage...

Page 15: ...ly used by Newport are 26LS31 or MC3487 Reception circuits to use are 26LS32 or MC3486 5 4 Feedback Signal Position The incremental sensor consists of a optical scale and an encoder head When the carr...

Page 16: ...ls Encoder Phase B Encoder Phase B Encoders Sensors Power Supply 5 V 5 150 mA max 0 V Pin 24 Pin 20 Encoder Phase A Encoder Phase A Pin 23 Pin 19 Index Pulse Phase I Index Pulse Phase I Pin 25 Pin 15...

Page 17: ...unit from damage be sure to Keep all air vents free of dirt and dust Keep all liquids away from the unit Do not expose the unit to excessive moisture 85 humidity Read this manual before using the unit...

Page 18: ...interface connector Check that the option number specified on this label correspond to the number indicated in the driver module options table for your stage 6 3 Cables Our VP 25XA stage is delivered...

Page 19: ...when a VP 25XA stage is used with non Newport electronics WARNING Maximum characteristics used for CE compliance UE25CC DC motor 48 V 0 9 A peak to peak Sub D25 male Connector 9 10 11 12 1 2 3 4 5 6...

Page 20: ...rface of a M VP 25XA stage to make an XY assembly for example To do so just unscrew the 4 CHc M4 x 12 100 x 75 screws of the top plate with the wrench supplied with the stage 110 3 12 7 75 4 holes 4 5...

Page 21: ...Assemblies 9 1 XY Mounting 4 holes M4 thd 100 x 75 27 91 Floating Carriage CAUTION To make an XY stage assembly it is necessary to tighten screws firstly on the driving carriage of the lower stage th...

Page 22: ...d depth 6 2 x 2 holes 1 6 9 525 spacing Note Dimensions in millimeters A B C D VP BK 1 4 20 25 4 8 32 4 40 M VP BK M6 25 M4 M3 F G H I J VP BK 13 1 50 8 25 4 16 3 58 8 M VP BK 13 5 50 25 16 5 59 K L M...

Page 23: ...ery 2000 hours of use for lubrication If your VP 25XA stage is mounted on a workstation and cannot be easily dismantled please contact our After Sales Service for further instruc tions 10 2 Repairing...

Page 24: ...P O Number Item s Being Returned Model Description Reasons of return of goods please list any specific problems Return authorization Please obtain prior to return of item Date Phone Number Fax Number...

Page 25: ...l tech newport com Service RMAs Returns Tel 800 222 6440 e mail rma service newport com Europe MICRO CONTROLE Spectra Physics S A S 1 rue Jules Guesde B t B ZI Bois de l pine BP189 91006 Evry Cedex Fr...

Page 26: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...