WS
wait for motion stop
IMM
PGM
MIP
USAGE
♦
♦
♦
SYNTAX
xx
WS
nn
PARAMETERS
Description
xx
[ int ] -
axis number
nn
[ int ] -
delay after motion is complete
Range
xx
-
0
to
MAX AXES
nn
-
0
to
60000
Units
xx
-
none
nn
-
milliseconds
Defaults
xx
missing:
error 37, AXIS NUMBER MISSING
out of range:
error 9, AXIS NUMBER OUT OF RANGE
motion is complete and then executes the next commands.
WP
-
wait for position
nn
missing:
error 38, COMMAND PARAMETER MISSING
out of range:
error xx2, PARAMETER OUT OF RANGE
DESCRIPTION
This command stops the program execution until a motion is completed. The
program is continued only after axis
xx
reaches its destination. If
xx
is not
specified, the controller waits for all motion in progress to end. If
nn
is specified
different than 0, the controller waits an additional
nn
milliseconds after the
Note:
Wait commands are primarily intended for use in internal program execution or
in combination with the RQ command. If used in command mode, it is important
to note that input command processing is suspended until the wait condition has
been satisfied.
RETURNS
none
REL. COMMANDS
WT
-
wait
EXAMPLE
2PA10;
2WS500
;3PA5 |
move axis # 2 to position 10 units, wait for axis # 2 to
|
reach destination, wait an additional 500ms and then
|
move
axis # 3 to position 5 units
3-154
Section
3
–
Remote
Mode
Summary of Contents for ESP300 Series
Page 1: ...ESP300 Motion Controller Driver User s Manual...
Page 4: ...ESP300 1999 EU Declaration of Conformity iv Preface...
Page 29: ...This page is intentionally left blank Section 2 Modes of Operation 1 15...
Page 30: ......
Page 230: ...4 16 Section 4 Advanced Capabilities...
Page 274: ...This page is intentionally left blank 6 6 Section 6 Servo Tuning...
Page 290: ...This page is intentionally left blank B 6 Appendix B Trouble Shooting and Maintenance...