VI) SPECIFICATIONS

8

1

Input:

115/230 VAC + 10%, 50-60 Hz.

Output:

13.8 VDC
20 Amps Surge (10% duty cycle, 10 minutes max.)
5 Amps continuous (100% duty cycle)

Regulation:

1% Line and Load

Ripple:

4 mV RMS (@5 amp continuous duty rating)

Current Limit:

Power supply current limit set @ 110% of continuous
duty rating.

Low Voltage Alarm:

Engages @ 10.6 - 10.9 VDC Output
Terminal Voltage

Low Voltage Disconnect:

10.3 VDC Output Terminal Voltage

Internal Battery(s):

Sealed, Lead-Acid, Rechargeable, Deep-Cycle
12 Volt, 7 Amp-Hour

Back-Up Battery Float Voltage:

13.8 VDC

Dimensions (H x W x D):

5.25" x 9" x 10.5"

Weight:

16 Ibs. (with one battery)
22 Ibs. (with two batteries)