 key repeatedly will step the display through

Battery 1, 2, 3, 1, etc.  To display the Capacity Remaining

(Amp-Hours % Remaining), press the 

and

keys simultaneously.

Setting High Volts Alarm

While viewing Battery #1 volts, press and hold the 

key

for ten (10) seconds.  You will hear a beep and the High

Volts alarm value will be displayed.   Use the 

and

keys to set the desired alarm value.   Press the 

 key

for 1/2 second to save the High Volts Alarm value to
memory.

Setting Low Volts Alarm

While viewing Battery #1 volts, press the

key for ten (10)

seconds.  You will hear a beep and the Low Volts alarm

value will be displayed.  Use the 

and 

keys to set the

desired alarm value.   Press the

key for

1/2 second to save the new alarm value.

Setting Low Amp-Hours Alarm

While viewing Amp-Hours, press and hold the

key for

ten (10) seconds.  You will hear a beep and the Low Amp-

Hours alarm value will be displayed.  Use the 

and

keys to change it.   Press the

key for 1/2 second to

save the new value.

Changing Battery Capacity

Press and hold the 

 key while applying power to the

DCE.  The Battery Capacity (in Amp-Hours) will be

displayed.   Use the 

and 

keys to change it.   Press

the

key for 1/2 second to save it.

Changing Charge Efficiency

The Default Charge Efficiency is 80% (meaning you get
back 80% of what you put into the battery).  To change it,

press and hold both the

and

 keys and apply power to

the DCE.  Charge Efficiency % is displayed. Use

the

and

keys to change it.   Press the

key for 1/2

second to save the new value.

Changing Peukert's Exponent

Peukert's Exponent relates how efficiently you can draw
current from a battery.  Because of inefficiencies, the faster
you drain the battery, the smaller it appears to be.  The
default Peukert's Exponent is 1.25 (shown as 125), which is
typical for many batteries.  To change it,  press and hold the

and

 keys while applying power to the instrument.

Peukert's exponent will be displayed.  Use the 

and

keys to set the desired  value.   Press the

key for 1/2

second to save the new value.  If your battery seems to
discharge faster than what the DCE is telling you, try
increasing Peukert's Exponent slightly.  Lower the exponent
if the reverse is true.  The correct setting will depend upon
how your battery was manufactured and it's age, etc.

NMEA 0183 Sentences

Volts:

 $IIXDR,U,xx.x,V,VAH35,*CS

Amps:

 $IIXDR,I,xxxx,A,VAH35,*CS

A-H Remaining:

 $IIXDR,G,xxxx, ,VAH35,*CS

*CS = Check Sum

Selecting NMEA 0183, External Alarm or Charger Control
Output

Screw terminal pin (B) can be programmed as an NMEA
0183 Data Output, External Alarm Output, or as a Charger
On-Off Control. The factory default is NMEA 0183 serial
data output.

To toggle Screw Terminal Pin (B) between NMEA 0183,
External Alarm Output and Charger Control, press and hold

down both the

and 

 

keys for 10 seconds (until you

hear a long beep).  The display will toggle between showing
“dAtA” (Data), “E-AL” (External Alarm) or “-CC-”
(Charger Control) to show you which mode is selected. The
new output mode is automatically saved to memory.

A 5V signal (10 mA Max.) is output on screw terminal (B)
whenever an alarm condition exists and the alarms are
enabled or whenever a charger is to be turned on
automatically.

Summary of Contents for DCE

Page 1: ...0 amp 50mV shunts Unit must be recalibrated if other than 500 amp shunt is used Installation Before starting the installation please read this entire section first The instrument may be installed in a bulkhead or in NEWMAR s Single or Dual Universal Meter Panel Blanks contact factory Remove the rear bracket attach wiring as explained in the following section then reassemble and install as shown in...

Page 2: ...e above proce dure until it does Calibrating Zeroing the Instrument The DCE is factory calibrated and under most circum stances should not require re calibration after being installed If however you suspect then confirm incorrect Return to SHUNT Fuse H and G also if used to DC Negative voltage and or amperage readings the unit may be re calibrated as follows To re calibrate the voltmeter press and...

Page 3: ... and keys to change it Press the key for 1 2 second to save the new value Changing Peukert s Exponent Peukert s Exponent relates how efficiently you can draw current from a battery Because of inefficiencies the faster you drain the battery the smaller it appears to be The default Peukert s Exponent is 1 25 shown as 125 which is typical for many batteries To change it press and hold the and keys wh...

Page 4: ... will start to lose accuracy This is because small calibration and measurement errors can accumulate causing the displayed amp hours to drift so that it no longer reflects true amp hours remaining To minimize this long term drift you can program an amp hours drift compensation value between 0 and 100 which will increase the accuracy The nominal drift value is 55 To change this value press and hold...

Reviews: