Noise 

Ripple

  

Below 100Hz   

<1mV

RMS

 Unweighted 

Voice band

 

100Hz to 5 kHz  

<1mV

RMS

 Psophometric  

Wide band

 

5 kHz to 1MHz   

<5mV

RMS

 Unweighted 

Peak to Peak

  0 to 20MHz 

 

<50mV Peak to peak 

Isolation 

Input to Input

  

4000V 

DC 

Input to Chassis

 

3500V DC (VDR to chassis removed)  

Output to Chassis

 2100V 

DC 

3.3 Environmental 

Operating Ambient Temperature 

Rated

  

 

25± 

ºC 

Range

   

 

-10ºC to 70ºC 

Storage Temperature

   

-20ºC to 70ºC 

Humidity

 

 

 

5 – 95% RH (non-condensing) 

Altitude <

2500m above sea level 

De-rate maximum ambient temperature by 4ºC 
per 1000m above sea level. 

3.4 Mechanical 

Dimensions (W, H, D)   

111.5mm (4.39”), 44mm (1.73” or 1U), 282mm overall                                               

jajljafjlajflkajlfjalfjaljflajdfljasdlfjaljf

(260mm/10.23” shelf) 

Weight 

   1.5kg 

(3.31 

lbs.) 

Shipping Dimensions (W, H, D)  120mm (4.7”), 52mm (2.05”), 325mm (12.8”) 

Shipping Weight 

 

1.6kg (3.53 lbs.) 

3.5 Compliances 

Safety 

   EN60950 

Electrostatic Discharge   

CISPR 24 

Radiated Radio Frequency 

CISPR 22 

AC Harmonics   

 

EN 61000-3-2 

AC Flicker and Fluctuation 

EN 61000-3-3 

Other 

   CE 

RoHS 

compliant 

 

Due to ongoing product development specifications are subject to change without prior notice. 

Summary of Contents for C2R-1000

Page 1: ...00 854 3906 Newport Beach CA USA Centurion II Power System 24 VDC 1000 Watt 48 VDC 2000 Watt Rectifier Installation Operation Manual Model C2R 2000 Newmar 2911 W Garry Ave Santa Ana CA 92704 Tel 714 7...

Page 2: ...1 10 Fan Cooling 3 1 11 Serial Alarm and Control Interface 3 1 11 1 Voltage Control 4 1 11 2 Rectifier Alarm states 4 1 11 3 Rectifier Shutdown 4 1 12 Post mate Connection 4 1 13 Interface Rear Conne...

Page 3: ...ators There are 3 LED indicators on the front panel indicate the operational state of the rectifier AC This green LED indicates that mains power is connected to the unit and that the primary stages of...

Page 4: ...the rectifier will de rate its output power to keep internal temperatures within the allowable range 1 8 Reverse Polarity Protection The rectifier has an internal reverse polarity protection fuse and...

Page 5: ...l The AC supply is not present at the rectifier Rectifier Fail The rectifier is not functioning This could be due to high output voltage AC failure or a fault with the rectifier internally Over Temper...

Page 6: ...Description Pin 1 2 3 Positive Output Pin 4 5 6 Negative Output Pin 7 Serial Communication Bus Pin 8 Rack Position horizontal Pin 9 Rack Position vertical Pin 10 Post mate connected to negative output...

Page 7: ...efficiently as possible ensure the following The air at the front of the rack is at ambient temperature and not being heated by other equipment Ensure the rectifier shelf has at least 75mm 3 clear ho...

Page 8: ...1 Ensure the polarity of the load and battery cables to the backplane is correct 2 Plug the rectifier into the rectifier shelf using the following steps Locate the metal tag at the bottom rear of the...

Page 9: ...voltage restored Input Inrush 2x maximum input current 3 2 DC Output Software Switchable Nominal 48V 24V Rated Voltage 58V 29V Adjustable Voltage Range 43V 60V 21V 30V Maximum Rated Current 41 7A 41...

Page 10: ...ure 20 C to 70 C Humidity 5 95 RH non condensing Altitude 2500m above sea level De rate maximum ambient temperature by 4 C per 1000m above sea level 3 4 Mechanical Dimensions W H D 111 5mm 4 39 44mm 1...

Page 11: ...If the yellow LED is alight Check the monitor Non Urgent Alarm list 4 3 Fuses Although there are fuses inside the rectifier these are rated such that their failure indicates a fault requiring qualifi...

Page 12: ...11 Newmar PO Box 1306 Newport Beach CA 92663 Phone 714 751 0488 E mail techservice newmarpower com 5 Ventilation Details...

Page 13: ...ned damage by power surges or electrical storms or sustained shipping damage or repaired by any unauthorised repair centre Please contact Newmar Customer Service to obtain a Returned Materials Authori...

Reviews: